Technical data

   Page 20
5.3. Power, Control Indicators, Reset and Grounding
5.3.1 Power Connector
Fig.5-16: DC Power connector on the bottom (rear) side of the OIC Panel system
The DC Power connector (refer to Fig.5-15, #11 and Fig.5-16) provides the power connection of the Operator
Interface Computer 10"/15"/17NEMA4 system, IP10IA99 / IP15IA99 / IP17IA99 to the main power source via the
DC power cable or the AC/DC adapter.
5-pin terminal block connector for power inlet from the adaptor to the unit. 3-pin is the power (V+ / NC / V-)
supplied from a wide input range DC +12V ~ +24V (± 20% tolerance); while the other 2-pin serves the UPS-like
purpose. If the AC power source is failed and no power inputs to the DC adaptor, the other 2-pin on the right side
of the connector can supply the power to the unit from the standby UPS.
Table 5-1: Electrical Specifications for the Panel System
System Type
Product
Input
Operator Interface
Computer 10"/15"/17”
NEMA4 system
IP10IA99 24V DC 1.49A max.
12V DC 2.93A max.
IP15IA99 24V DC 1.73A max.
12V DC 3.46A max.
IP17IA99 24V DC 2.18A max.
12V DC 4.16A max.
5.3.1.1 Power Button and Power LED
The Operator Interface Computer 10"/15"/17” NEMA4 system, IP10IA99 / IP15IA99 / IP17IA99, provides a power
button (refer to #4, Fig.5-13) and a power LED (refer to #5, Fig.5-13) on the front panel.
The power button allows to Power ON/OFF Operator Interface Computer 10"/15"/17” NEMA4 system, IP10IA99 /
IP15IA99 / IP17IA99, depending on the settings for the power button in BIOS Setup (default setting is Power/After
Power Failure/ON).
The power LEDs show the ON/OFF state of the system. The OIC (Operator Interface Computer) 10"/15"/17”
NEMA4 system, IP10IA99 / IP15IA99 / IP17IA99 is equipped with a power LED on the front panel (refer to Fig.5-17).
An additional power LED (PWR) is available on bottom (rear) side of the system (refer Fig.5-18).