Installation manual
SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013  Page 17 of 20
Parameter Description:
Cycled Fan:•   When set for “Cycled”, the fan will operate on demand. When set for “Continuous”,  
  the fan will always operate when the system is in cool mode.
System Units:•   Degrees Fahrenheit (°F) or degrees Celsius (°C) can be selected
Display Brightness:•   Display brightness can be set from 4 to 15 to suit room lighting conditions. 
Screen Saver Brightness:•   If set for (0) then a single bar will blink sequentially in the four corners  
  of the display. Values from 1 to 8 can be set to suit room lighting conditions.
Temperature Calibration:•   This parameter allows the user to calibrate the room air temperature  
  sensor. The room temperature will be displayed and can be adjusted +/-10 °F or +/-5°C
Staging Delay:•    The compressor staging delay is provided for multi system installations. Set the  
  Staging  delays  at  different  intervals  so  only  one  compressor  starts  at  a  time  when  power  is  
  applied. 
De-Ice Time:•   If the compressor runs continuously for longer than one hour, the compressor will  
  shut down and the blower will run for the specied time. The compressor will then restart and  
  resume operation.
Cycled Pump:•   When set for “Cycled”, the pump will run on demand. When set for “Continuous”,  
  the pump will run continuously when the system is in cool mode.
Fan  Speed  1-6:•    These  parameters  are  used  to  optimize  fan  performance  and  airow  Speed  1  
  corresponds to the lowest speed setting. Speed 6 corresponds to the highest speed setting. Speeds  
  should be set to avoid system icing in humid environments.
Maximum Comp Current:•   Thirty seconds after starting a cooling cycle the compressor current  
  will be limited to this value.
Compressor  Speed  Range:•    The  number  of  degrees  from  set  point  to  maximum  compressor  
  speed.
Reset Parameters:•   To reset all parameters to factory defaults, select YES and then exit the program  
  mode by pressing the on / off button. The display will show “EEPROM RESET”, and then show  
  the room temperature in the off mode. 
Programmable Parameters Table:
Description Default Value
Cycled fan  Continuous Cycled or Continuous
System units °F °F or °C
Display brightness 15 4=Minimum 15=Maximum
Screen saver brightness 4 - and 1-8
Temperature calibration 0 Ambient +/- 10°F
Staging delay 15 5-135 Seconds
De-Ice time 2 1-5 Minutes
Cycled pump Cycled Cycled or Continuous
Fan A speed 1 30 30-90
Fan A speed 2 35 30-90
Fan A speed 3 40 30-90
Fan A speed 4 45 30-90
Fan A speed 5 55 30-90
Fan A speed 6 85 30-90
Compressor speed range 2 (1.1) 2-5 °F (1.1-2.8 °C)
Maximum comp current 35 Off, 10-60 Amps
Reset Parameters No No or Yes