Installation manual
SeaMach 24 VDC
Rooftop Air Conditioners
SeaMach 24 VDC Rooftop Air Conditioner Installation Manual 5/2013  Page 14 of 20
Chapter 9 - Completing The Installation (9000 Series)
Make sure the non-allergenic lters are properly positioned in the ceiling grille.A. 
Install the ceiling grille by positioning on the bottom of the shroud and engaging the two 1/4 turn fasteners.B. 
Turn the selector switch to OFF positionC. 
Turn ON the power supply to the roof top air conditioner.D. 
System Checkout – Airxcel, Inc. manufactures a wide range of roof top air conditioners which incorporate different product E. 
operation features. To properly evaluate the performance of a newly installed air conditioner, it is necessary to review the 
specic unit operation characteristics (features) described in the product operation and maintenance instructions (Customer 
Envelope Package).
Chapter 10 - Installation, Programming and Operation of the 
o-Touch Thermostat
Introduction
When  connected  to  a  12-24VDC  controller,  the  versatile  o-Touch  DC  digital  display  provides  room 
temperature control and humidity reduction in a small package. It allows for easy control of fan speed, 
operating mode and temperature in a wide variety of applications. 
 Features Include:
Easy touch screen operation.• 
Built in room temperature sensor.• 
The display is compatible with Vimar and Gewiss frames. • 
Visual symbols enable the viewer to see the operating status at a glance.• 
Easily programmed for customized operation.• 
Both automatic and manual six level fan speed control.• 
De-icing cycle to prevent evaporator icing.• 
Automatic moisture mode provides relative humidity control.• 
Variable compressor speed control reduces power consumption as ambient temperature approaches  • 
  the set point.
Compressor current limiting can be used to prolong battery life.• 