Specifications
  7
FIGURE 2 
CONNECT 115 VAC WIRING 
1.    WARNING – SHOCK HAZARD 
  To prevent the possibility of severe personal 
  injury or equipment damage due to electrical 
  shock, always be sure the electrical power is 
  disconnected or off before beginning  
  installation. 
2.  Complying with the “Danger” notice below, bring the 
  115 VAC supply wiring previously routed into the 
  frame of the roof opening, through the strain relief 
  atop the electrical box and into the high voltage 
  wiring area. 
DANGER 
  WHEN USING NON-METALLIC SHEATH 
  SUPPLY CABLES (ROMEX, ETC.), STRIP 
  SHEATH BACK TO EXPOSE 4-6 INCHES 
  OF THE SUPPLY LEADS. STRIP THE 
  INDIVIDUAL WIRE LEAD ENDS FOR  
  WIRE CONNECTION (ABOUT 3/4" BARE 
  WIRE). INSERT STRAIN RELIEF INTO 
  ELECTRICAL BOX. INSERT THE 
  SUPPLY WIRES THROUGH THE STRAIN 
  RELIEF. 
(ON SOME UNITS, THERE WILL
BE MACHINE SCREWS AT
THESE LOCATIONS)
-