RV Products Division INSTALLATION INSTRUCTIONS FOR 48000 SERIES AIR CONDITIONERS CLIMATISEURS SÉRIE 48000 INSTRUCTIONS D’INSTALLATION
TABLE OF CONTENTS I. II. III. IV. V. VI. VII. VIII. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Conditioning Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selecting an Installation Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the Roof Top Unit . . . . . . . . . . . . . .
II. AIR CONDITIONING SIZING The ability of an air conditioner to provide a comfortable environment for the consumer is dependent upon the following conditions. As a general rule, air supplied (discharge air) from the air conditioner will be 15 to 20 degrees cooler than the air entering (return air) the ceiling assemblies bottom air grilles. Air conditioners are rated primarily by their ability to remove heat.
After the support frame is installed, seal off all gaps between the frame and both the roof exterior and the interior ceiling of the vehicle (cavity walls). Additionally, seal the gap around the electrical supply wiring. location of any inner roof plumbing and electrical supplies must be considered. A. If a roof vent is already present in the desired mounting location for the air conditioner, the following steps must be taken: 1. B. Remove all screws which secure the roof vent to the vehicle.
7 DEGREE MAX. ABOVE LEVEL 7 DEGREE MAX. ABOVE OR BELOW LEVEL NOTE: IF UNIT IS INSTALLED UNLEVEL FRONT TO BACK, THE NOSE OR FRONT OF THE UNIT MUST BE UP. DO NOT INSTALL NOSE DOWN. ALLOWABLE OFFSET FOR ALL HEAT PUMPS WITH RECIPROCATING COMPRESSORS. FIGURE 2 15 DEGREE MAX. ABOVE LEVEL 15 DEGREE MAX. ABOVE OR BELOW LEVEL NOTE: IF UNIT IS INSTALLED UNLEVEL FRONT TO BACK, THE NOSE OR FRONT OF THE UNIT MUST BE UP. DO NOT INSTALL NOSE DOWN. ALLOWABLE OFFSET FOR ALL HEAT PUMPS WITH ROTARY COMPRESSORS.
V. SECURING THE AIR CONDITIONER TO THE ROOF A mounting frame is supplied with the ceiling assembly. Follow the steps below to secure the air conditioner to the roof. Refer to Figure 5. A. Locate the air conditioner mount gasket over the 14” to 15” square opening in the roof. B. Install the ceiling assembly mount frame using the four bolts found with the ceiling assembly. C.
VI. ELECTRICAL WIRING SHEATH CABLE IS CENTERED IN CLAMP BEFORE TIGHTENING UP ON IT. DO NOT OVERTIGHTEN!! ROUTING 115 VAC WIRING Following Airxcel’s high voltage wiring specifications and all local and national electrical codes, route the roof top unit 115 VAC supply wiring from its power source to the wirebox. THIS COULD RESULT IN PINCHING THROUGH THE PLASTIC WIRE INSULATION AND CAUSE SHORTING OR “HOT” WIRES TO GROUND (SHOCK HAZARD). THE CLAMP IS INTENDED FOR STRAIN RELIEF OF THE WIRES.
K. If the heater option is installed at this time, position the heater assembly in the air conditioner return air opening as shown in Figure 6. The heater bracket must be installed over the metal basepan extrusion and positioned between the basepan and the plastic drain pan (See Figure 7). Tighten set screw to secure the assembly so as to prevent movement. Pull the fabric duct material through ceiling assembly discharge opening. Peel the release liner from the adhesive strip around the discharge opening.
FIGURE 8 FIGURE 9 FIGURE 10 9
VIII. COMPLETING THE INSTALLATION (9000 SERIES) A. Make sure the non-allergenic filters are properly positioned in the ceiling grille. B. Install the ceiling grille by positioning on the bottom of the shroud and engaging the two 1/4 turn fasteners. C. Turn the selector switch to OFF position. D. Turn ON the power supply to the roof top air conditioner. E. System Checkout – Airxcel, Inc. manufactures a wide range of roof top air conditioners which incorporate different product operation features.
I. RENSEIGNEMENTS GÉNÉRAUX OEM (Fabricant d’équipement d’origine) – Veuillez vous assurer que la pochette de documentation accompagne le climatiseur. QUESTIONS SUR LE CLIMATISEUR – Pour toutes questions au sujet de l’installation du produit adressées à votre représentant Airxcel, Inc. ou à Airxcel, Inc., veuillez indiquer les numéros de modèle et de série du climatiseur de toit.
Autocaravanes – un seul appareil ou l’avant de deux appareils devrait être monté jusqu’à 9 pieds (2,74 mètres) du poste de conduite. Fourgonnettes – l’emplacement devrait être au centre du toit (d’un côté à l’autre – d’avant en arrière). Camion avec caisse de camping – l’emplacement devrait être entre 4 et 5 pieds (1,2 et 1,5 mètres) de l’arrière de la caisse de camping pour obtenir un refroidissement maximum.
D. Le climatiseur de toit doit être monté aussi à niveau que possible, d’avant en arrière et d’un côté à l’autre, lorsque le véhicule est stationné sur une surface plane. Les figures 2 et 3 illustrent les déviations maximales premises (degrés de montage de la surface plane de la surface totale). E.
DANGER DANGER DE CHOC ÉLECTRIQUE NORMALEMENT D’UNE LÉGÈRE PRESSION. POUR ÉVITER LA POSSIBILITÉ DE BLESSURES SUITE À DES CHOCS ÉLECTRIQUES, LE FIL BLANC DOIT ÊTRE CONNECTÉ AU NEUTRE À L’ENTRÉE DU COFFRET DE BRANCHEMENT ET LA MASSE MÉCANIQUE CONNECTÉE À UNE COSSE DE MASSE SOIT DANS LE COFFRET DE BRANCHEMENT OU DANS LE COMPARTIMENT DU MOTEURGÉNÉRATEUR.
seront pas pincés par l’écran de la boîte des commandes. Cet écran est bien installé lorsque les deux trous de l’écran sont alignés avec les trous des deux vis dans le guide du montage de plafond (voir figure 8). I. J. se fait sur un plafond plat et s’il y a des écarts sur les côtés de l’épaulement, insérez les quatre vis optionnelles de 3/4 de pouce (1,9 cm) (fournies) à travers les montants et fixez-les au cadre de montage situé au-dessus (voir figures 8, 9 et 10 pour l’implacement des vis).
RV Products Division Airxcel, Inc. RV Products Division P.O.