Specifications
Electrical Control Function   
94  Electrical Control System 
Low indoor room temperature protection 
All protections are active and the same as that in cooling mode. 
For other models:   
Indoor fan speed is fixed at breeze and can’t be changed. The louver angle is the same as in cooling mode. 
Low indoor room temperature protection 
In drying mode, if room temperature is lower than 10℃, the compressor will stop and not resume until room 
temperature exceeds 12℃. 
All protections are active and the same as that in cooling mode. 
1.3.6 Timer function 
1.3.6.1 Timing range is 24 hours. 
1.3.6.2 Timer on. The machine will turn on automatically when reaching the setting time. 
1.3.6.3 Timer off. The machine will turn off automatically when reaching the setting time. 
1.3.6.4 Timer on/off. The machine will turn on automatically when reaching the setting “on” time, and then 
turn off automatically when reaching the setting “off” time. 
1.3.6.5 Timer off/on. The machine will turn off automatically when reaching the setting “off” time, and then 
turn on automatically when reaching the setting “on” time. 
1.3.6.6 The timer function will not change the AC current operation mode. Suppose AC is off now, it will not 
start up firstly after setting the “timer off” function. And when reaching the setting time, the timer LED will be 
off and the AC running mode has not been changed. 
1.3.6.7 The setting time is relative time. 
1.3.7 Economy function 
1.3.7.1 The sleep function is available in cooling, heating or auto mode. 
1.3.7.2. Operation process in sleep mode is as follow: 
When cooling, the  setting temperature rises 1℃  (be lower than 30℃) every one  hour, 2 hours later the 
setting temperature stops rising and the indoor fan is fixed at low speed.     
When heating, the setting temperature decreases 1℃  (be higher than 17℃) every one hour, 2 hours later 
the setting temperature stops rising and indoor fan is fixed at low speed. (Anti-cold wind function has the 
priority). 
1.3.7.3 Operation time in sleep mode is 7 hours. After 7 hours the AC quits this mode, the unit will turn off. 
1.3.7.4 Timer setting is available 
1.3.8 Auto-Restart function 
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart module. In 
case of a sudden power failure, the module memorizes the setting conditions before the power failure. The 
unit will resume the previous operation setting (not including Swing function) automatically after 3 minutes 
when power returns. 