Specifications
Electrical Control Function
Electrical Control System 89
T4
A DC_FAN_HI_SPD_ADD
B DC_FAN_MID_SPD_ADD
C DC_FAN_MIN_SPD_ADD
D DC_FAN_SLOW_SPD_ADD
E DC_FAN_SSLOW_SPD_ADD
23℃
22℃
20℃
28℃
19℃
17℃
26℃
25℃
1.3.2.3 Indoor fan running rules
For Cassette、A5
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto.
The auto fan:
3.5
3.0
High
Low
1.0
Medium
1.5
For HKD,HND, Console:
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto.
When the compressor is running, the indoor fan is controlled as below: