Specifications
  Product specification 
General Information  7 
Model Outdoor Unit 
AWAU-YCZ536-H11 
Installation Method of Pipe 
5 x AWSI-HND009-N11 
5 x AWSI-HKD009-N11 
Installation Method of Pipe 
Flared 
Flared 
Characteristics 
Units 
Cooling 
Heating   
Cooling 
Heating   
Average 
Average 
Capacity 
(1)
kW 
10.5 
11.5 
10.5 
11.5 
Pdesign 
kW 
10.5 
10.5 
10.5 
10.5 
SEER / SCOP 
(2)
W/W 
5.6 
3.8 
5.1 
3.8 
Energy efficiency class 
A+ 
A 
A 
A 
Annual energy consumption 
kWh 
656 
3868 
721 
3868 
Tbiv 
o
C 
N/A 
-7 
N/A 
-7 
Tol 
o
C 
N/A 
-15 
N/A 
-15 
Power supply 
V/Ph/Hz 
220-240V/Single/50Hz 
Circuit breaker rating 
A 
32 
Rated power input (Maximum power input) 
kW 
4.9 
Rated current (Maximum current) 
A 
22 
OUTDOOR
Refrigerant control 
Capillary +EXV 
Compressor type. model 
Twin Rotary DC Inverter 
Fan type & quantity 
Axial x 1 
Fan speeds 
H/L 
RPM 
850 
Air flow   
H/L 
m3/hr 
5500 
Sound power level
(4)
H/L 
dB(A) 
70 
Sound pressure level
(5)
H/L 
dB(A) 
60 
Dimensions 
WxHxD 
mm 
990x345x965 
Weight 
kg 
80 
Package dimensions 
LxWxH 
mm 
1120x435x1100 
Packaged weight 
kg 
91 
Stacking height 
units 
2 levels 
Refrigerant type 
R410A 
Refrigerant charge (standard connecting tubing length) 
kg(10m) 
3 
Additional charge per 1 meter 
gr / 1m 
25m<L<30m 15g/m 
Connections 
between 
units 
Liquid line 
In.(mm) 
5x1/4”(Φ6.35) 
Suction line 
In.(mm) 
5x3/8”(Φ9.52) 
Max. length for all rooms 
m 
75 
Max. length for one indoor unit 
m 
30 
Max. height 
difference 
between 
indoor and 
outdoor unit   
OU higher than IU 
m 
10 
OU lower than IU 
m 
15 
Max. height difference between indoor 
units   
m 
10 
Operation control type   
Remote control 