Service manual

SPECIFICATION
HKD DCI 9 Version - 1
3. Specification
Model Indoor Unit
AWSI-HKD009-N11
Model Outdoor Unit
AWAU-YKD009-H11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Capacity
(1)
kW
2.70(1.0~3.2)
2.8(1.0~3.4)
Pdesign
kW
2.7
2.4
SEER /SCOP
(2)
W/W
5.8
3.8
Energy efficiency class
A+
A
Annual energy consumption
kWh
163
884
Tbiv
o
C
N/A
-7
Tol
o
C
N/A
-15
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
10
INDOOR
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L
RPM
1150/1000 /800
1150/1000/ 800
Air flow
(3)
H/M/L
m3/hr
620/540/440
620/540/440
External static pressure
Min-Max
Pa
0
Sound power level
(4)
H/M/L
dB(A)
58
Sound pressure level
(5)
H/M/L
dB(A)
42/38/30
Moisture removal
l/hr
1.0
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
800 x275x188
Weight
kg
6.5
Package dimensions
LxWxH
mm
865 x350x265
Packaged weight
kg
9.5
Stacking height
units
8
OUTDOOR
Refrigerant control
Capillary tube
Compressor type, model
Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
800
Air flow
H/L
m3/hr
1800
Sound power level
(4)
H/L
dB(A)
64
Sound pressure level
(5)
H/L
dB(A)
52
Dimensions
WxHxD
mm
780 x540x250
Weight
kg
27.5
Package dimensions
LxWxH
mm
910x335x585
Packaged weight
kg
30
Stacking height
Units
5
Refrigerant type
R410A
Refrigerant charge (standard connecting tubing length)
kg(5m)
0.8
Additional charge per 1 meter
gr / 1m
15
Connections between units
Liquid line
In.(mm)
1/4" (6.35)
Suction line
In.(mm)
3/8"(9.52)
Max.tubing length
m.
20
Max.height difference
m.
8
Operation control type
Remote control
Heating elements
kW
Others