Service manual
SPECIFICATION                                                                                        
HKD  DCI                                                               9                                                            Version      -  1 
3. Specification 
Model Indoor Unit 
AWSI-HKD009-N11 
Model Outdoor Unit 
AWAU-YKD009-H11 
Installation Method of Pipe 
Flared 
Characteristics 
Units 
Cooling 
Heating 
Average 
Capacity 
(1)
kW 
2.70(1.0~3.2) 
2.8(1.0~3.4) 
Pdesign 
kW 
2.7 
2.4 
SEER /SCOP 
(2)
W/W 
5.8 
3.8 
Energy efficiency class 
A+ 
A 
Annual energy consumption 
kWh 
163 
884 
Tbiv 
o
C 
N/A 
-7 
Tol 
o
C 
N/A 
-15 
Power supply 
V/Ph/Hz 
220-240V/Single/50Hz 
Circuit breaker rating 
A 
10 
INDOOR   
Fan type & quantity 
Cross flow fan x1 
Fan speeds 
H/M/L 
RPM 
1150/1000 /800 
1150/1000/ 800 
Air flow 
(3)
H/M/L 
m3/hr 
620/540/440 
620/540/440 
External static pressure 
Min-Max 
Pa 
0 
Sound power level 
(4)
H/M/L 
dB(A) 
58 
Sound pressure level
(5)
H/M/L 
dB(A) 
42/38/30 
Moisture removal 
l/hr 
1.0 
Condensate drain tube I.D 
mm 
16 
Dimensions 
WxHxD 
mm 
800 x275x188 
Weight 
kg 
6.5 
Package dimensions 
LxWxH 
mm 
865 x350x265 
Packaged weight 
kg 
9.5 
Stacking height 
units 
8 
OUTDOOR 
Refrigerant control 
Capillary tube 
Compressor type, model 
Rotary DC Inverter 
Fan type & quantity 
Axial x 1 
Fan speeds 
H/L 
RPM 
800 
Air flow   
H/L 
m3/hr 
1800 
Sound power level
(4)
H/L 
dB(A) 
64 
Sound pressure level
(5)
H/L 
dB(A) 
52 
Dimensions 
WxHxD 
mm 
780 x540x250 
Weight 
kg 
27.5 
Package dimensions 
LxWxH 
mm 
910x335x585 
Packaged weight 
kg 
30 
Stacking height 
Units 
5 
Refrigerant type 
R410A 
Refrigerant charge (standard connecting tubing length) 
kg(5m) 
0.8 
Additional charge per 1 meter 
gr / 1m 
15 
Connections between units 
Liquid line 
In.(mm) 
1/4" (6.35)   
Suction line 
In.(mm) 
3/8"(9.52) 
Max.tubing length 
m. 
20 
Max.height difference 
m. 
8 
Operation control type   
Remote control 
Heating elements 
kW 
Others 










