Service manual

SPECIFICATION
HKD DCI 11 Version - 1
Model Indoor Unit
AWSI-HKD018-N11
Model Outdoor Unit
AWAU-YKD018-H11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Capacity
(1)
kW
5.0(1.4~6.2)
5.1(1.4~6.4)
Pdesign
kW
5
4.8
SEER /SCOP
(2)
W/W
6.5
3.8
Energy efficiency class
A++
A
Annual energy consumption
kWh
269
1768
Tbiv
o
C
N/A
-6
Tol
o
C
N/A
-15
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
16
INDOOR
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L
RPM
1100 / 800 / 700
1150 / 800 / 700
Air flow
(3)
H/M/L
m3/hr
730/480/400
760/480/400
External static pressure
Min-Max
Pa
0
Sound power level
(4)
H/M/L
dB(A)
58
Sound pressure level
(5)
H/M/L
dB(A)
43/40/33
Moisture removal
l/hr
1.7
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
940 x275x205
Weight
kg
9.5
Package dimensions
LxWxH
mm
1015 x350x265
Packaged weight
kg
12.5
Stacking height
units
8
OUTDOOR
Refrigerant control
Capillary tube
Compressor type, model
Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
800
Air flow
H/L
m3/hr
2200
Sound power level
(4)
H/L
dB(A)
65
Sound pressure level
(5)
H/L
dB(A)
55
Dimensions
WxHxD
mm
760 x590x285
Weight
kg
35
Package dimensions
LxWxH
mm
887x355x645
Packaged weight
kg
37.5
Stacking height
units
4
Refrigerant type
R410A
Refrigerant charge (standard connecting tubing length)
kg(5m)
1.25
Additional charge per 1 meter
gr / 1m
15
Connections between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
1/2"(12.7)
Max.tubing length
m.
20
Max.height difference
m.
8
Operation control type
Remote control
Heating elements
kW
Others