User's Manual
Table Of Contents
screen.
Launch “Airtraq Cam” application in PC. 
If the last camera connected to “Airtraq Cam” application is 
emitting Wi-Fi signal the application will automatically 
connect to it and show the Live Video screen. If it is a different 
A-390 then a screen will show up with all Cameras that are 
emitting Wi-Fi signal near the PC. Select the camera that you 
want to connect. Type its Wi-Fi password if it has been set. 
Click on Live Video and the PC will display real time video 
captured by A-390. The application will allow to record 
Video on the PC.
16. VIEW SYSTEM INFORMATION
Select “Settings” in main menu to see system information 
on the A-390 Screen.
17. TROUBLESHOOTING
Make sure that A-390 battery is properly charged.
Make sure that the last internal software version is installed.
18. UPDATING A-390 INTERNAL SOFTWARE
A-390 internal software can be upgraded using the “Airtraq 
Cam” App. 
The PC should have Internet connection in order to get the 
latest version of A-390 internal software “A-390SW_Vx.xx” 
from Airtraq website (www.airtraq.com).
Connect A-390 to a PC (Windows or Mac) through the USB 
cable provided and using the “Airtraq Cam” App. When the 
App is launched a screen will show up with the A-390 
connected to the PC. Only one A-390 at a time can be 
connected to the PC. 
Select “Cam Settings”. In “Cam Settings” screen select 
Software Upgrade. Once the software has been successfully 
upgraded a message will be shown on the PC.
Disconnect the cable between PC and A-390. Turn on A-390 
and check “About” on camera to confirm the new software 
version is installed.
19. CLEANING INSTRUCTIONS
The A-390 is a non-critical device. Recommended cleaning is 
14. CONNECTING WI-FI LIVE VIDEO & RECORDING ON 
TABLET / PHONE 
A-390 can connect via Wi-Fi to tablets and smartphones on 
iOS or Android. When Wi-Fi is enabled the A-390 cannot 
record on it is internal memory. If the user needs to record, it 
can be done on the connected device.
Each A-390 creates an ad-hoc Wi-Fi network named 
AIQ+DeviceID+4 numbers automatically generated.
Before starting to use a tablet/smartphone/PC with A-390, 
download from App Store SM or Google PlayTM the “Airtraq 
Cam” application and install it. Make sure that you have the 
latest available version installed in your device.
A-390 will always start with Wi-Fi disabled. To enable Wi-Fi 
go to Main Menu and press Wi-Fi icon . Wi-Fi icon will 
turn to and an icon will appear on the header of the 
screen.
If tablet/smartphone has iOS, go to Settings and select the 
Wi-Fi network created by the A-390 (Name = AIQ + Device 
ID+ 4 numbers automatically generated).
If tablet/smartphone has Android, open “Airtraq Cam” and 
select the Wi-Fi network created by the A-390 (Name = AIQ 
+ Device ID).
For the best image, increase screen brightness in your 
tablet/smartphone. 
To avoid incoming calls while using the smartphone, turn it on 
airplane mode and then turn Wi-Fi on.
Launch Airtraq-Cam App on tablet/smartphone, it will 
connect to A-390 after approximately 10 seconds.
Tap twice on the iPad
®
/iPhone
®
 to get full screen image.
“Airtraq Cam” App for mobile devices allows the user to 
record videos directly on the mobile device.
15. CONNECTING WI-FI LIVE VIDEO TO A PC 
Download to PC “Airtraq Cam” App (Windows or Mac) from 
downloads section in Airtraq website (www.airtraq.com) and 
install it.
A-390 will always start with Wi-Fi disabled. To enable Wi-Fi 
go to Main Menu and press Wi-Fi icon , Wi-Fi icon will 
turn to and an icon will appear on the header of the 
Select “Videos” from Main Menu.
• The screen will display a list of the recorded videos 
showing starting date/time and duration. Last recorded 
video will be first on the list.
• Navigate through different pages using Up and Down 
navigation icons and select the desired video.
• Action icons provide the following functions: play/pause 
and fast forward/rewind.
12. DOWNLOAD VIDEOS TO A PC 
Videos are recorded into the A-390 in avi format and named 
automatically with the device ID and date and time at which 
they were recorded “deviceid_yy_mm_dd_xxh_xxm_xxs.avi”.
Videos are downloaded connecting the A-390 to a PC 
(Windows or Mac) through the USB cable provided and using 
the “Airtraq Cam” App for Windows or Mac. When videos 
are downloaded they are also converted and its file size is 
significantly reduced without losing resolution.
When the App is launched, a screen will show up with the 
A-390 connected to the PC. Only one A-390 at a time can be 
connected to the PC. 
Click on “Manage Videos on Cam” icon and the App will 
display the list of videos stored into the A-390. Select the 
video to be downloaded and press the download icon. 
13. DELETE VIDEOS FROM INTERNAL MEMORY
To delete videos, connect the A-390 to a PC (Windows or 
Mac) through the USB cable provided and use the “Airtraq 
Cam” App for Windows or Mac. When the App is launched 
a screen will show up with the A-390 connected to the PC. 
Only one A-390 at a time can be connected to the PC. 
Click on “Manage Videos on Cam” icon and the App will 
display the list of videos stored into the A-390. Select the 
video to be deleted and press the delete icon. 
Alternatively, the user can delete by one click all videos stored 
on A-390. A warning message asking for confirmation will 
be shown. 
10. RECORD & AUTO-RECORDING
RECORDING IS DEACTIVATED WHEN A-390 CAMERA IS 
NOT INSERTED ONTO AN AIRTRAQ. 
To start recording when in Live Video press icon . While 
recording, the icon will change to and a timer will appear 
on the header of the screen. 
To stop recording press the “Stop Recording” icon . The 
screen will show a message informing that recording will stop 
in 5 seconds unless user presses “Cancel”.
When Auto-Recording function is activated, it will 
automatically start a new video recording every time the 
A-390 enters into Live Video.
Video files are recorded in avi format and stored in A-390’s 
internal memory. A-390 is able to store 200 videos (more 
than 10 hours of video.
WHEN WI-FI IS ACTIVATED, THE A-390 CANNOT RECORD 
TO ITS INTERNAL MEMORY. The user has the option to 
record in the mobile device or PC that is Wi-Fi connected to 
the A-390 through the corresponding recording button of the 
“Airtraq Cam” App.
When memory is full, the A-390 cannot record to its internal 
memory. The user has to save the videos to a PC and/or 
delete them. 
11. PLAY RECORDED VIDEOS ON A-390
A-390 WI-FI CAMERA
INDEX
1. A-390 Basic information
2. A-390 Components
3. A-390 Switches, indicators and connectors
4. A-390 Battery charge & charge status checking
4.1. Camera Docking Station
4.2. Airtraq Docking Station
5. Mounting the A-390 onto the Airtraq
6. Turn On/Off
7. Touch Panel & Menus
8. Initial Set Up
9. Paediatric Mode
10. Record & Auto-Record
11. Play recorded videos on A-390
12. Download videos to a PC (Via USB cable)
13. Delete Videos
14. Connecting Wi-Fi Live video and recording onto Tablet/Phone
15. Connecting Wi-Fi Live video to a PC
16. View System Information
17. Troubleshooting
18. Updating A-390 Internal Software
19. Cleaning Instructions
20. Operating, Storage And Transport
21. Technical Data
22. Regulatory
23. Disposal Instructions
24. Manufacturer’s Warranty
25. Important Safety Instructions
2.4. Battery charger
Must be connected to mains supply to charge the 3.7 volts, 
Li-Po Battery. 
Always use the provided mains power supply provided with 
A-390.
2.5. Docking station 
Accessory to facilitate charge of A-390. 
Docking Station can also be used to charge the A-360 
Airtraq Wi-Fi Camera.
The mains power supply is connected to the Docking Station 
through its micro USB connector. 
2.6. Storage case 
Accessory to store all above items. 
The A-390 can be charged when it is inside the storage case. 
Pass the battery charger cable to the inside of the storage 
case through the hole on its lateral side and connect the Micro 
USB directly to the A-390. 
It is recommended that the A-390 be stored and transported 
inside the storage case to protect the camera while not in use. 
3. A-390 SWITCHES, INDICATORS AND CONNECTORS
screen and the left charge indicator will become blinking 
orange. The A-390 will continue to operate for 
approximately 15 to 20 more minutes. The manufacturer 
recommends recharging the battery of the A-390 frequently 
to ensure its availability for use.
Service life for the rechargeable battery depends upon the 
number of charge-discharge cycles performed. The A-390´s 
battery is a service replaceable part, if its capacity falls below 
the acceptable levels please contact your supplier. The A-390 
should never be opened by unauthorized personnel. Internal 
battery can only be replaced by the manufacturer.
5. MOUNTING THE A-390 ONTO THE AIRTRAQ
To mount the A-390 onto the Airtraq: 
• Remove eyecup from Airtraq.
• Place A-390 onto Airtraq’s proximal end. Make sure 
the A-390 is fully inserted. 
• A-390 will automatically turn on and start in Live Video 
mode. 
• When using a paediatric Airtraq model press .A 
message will appear on the screen “Paediatrics Mode 
On”.
• Depending on intubation position, one may want to 
rotate the image 180 degrees to correct the glottis 
orientation, press the rotate icon to do it. 
To remove A-390 from the Airtraq once intubation is finished 
pull A-390 away from Airtraq.
6. TURN ON/OFF
A-390 can be started in two different ways, in both methods 
it will start in “Live Video” mode:
• Automatically by sliding A-390 onto an Airtraq.
• Pressing the automatic power button located on the 
base of the A-390.
Turning on will take approximately 3 seconds. 
To turn off the A-390 press the “Power off” icon on the main 
menu. The unit will show a message to the user and a 
“cancel” icon will appear and it will automatically shut down 
in 5 seconds unless the user cancels the action.
When A-390 is assembled onto the Airtraq, and there is no 
action from the user for 30 minutes, A-390 will shut down 
automatically. Before turning off the screen will show a 
8. INITIAL SET UP. CAMERA SETTINGS
Initial set up must be performed connecting the A-390 to a PC 
(Windows or Mac) through the USB cable provided and using 
the “Airtraq Cam” App. When the App is launched a screen 
will show up with the A-390 connected to the PC. Only one 
A-390 at a time can be connected to the PC. 
Launch the App and select “Cam Settings”. Camera settings 
can be changed by entering the desired values and pressing 
“Save Changes” Icon.
• Select Language: Scroll and select the desired language.
• Set Date and Time: Date and time is used to name video 
files recorded. Introduce current date and time. 
• Set Cam ID: Cam ID is used to name the Wi-Fi Network 
generated by the A-390. Any combination of a maximum 
of 10 letters/numbers. 
• Set optional Wi-Fi Password: Optionally, to better 
protect patient’s information activate Wi-Fi password. 
Wi-Fi password is used to block non-authorized devices 
from connecting to A-390. User can set it to any 
combination of a maximum of five letters/numbers. 
Auto-recording options can be set in the A-390 camera. Press 
“Settings” icon.
• Set Auto Recording Mode: The auto-recording function 
will automatically start a new video recording every time 
the A-390 goes into Live Video. Set it on or off as desired.
• Set Auto-recorded video maximum size: select the 
maximum video file size: (5 min [18 mb], 7 min [21 mb], 
10 min [30 mb], 15 min [45 mb], 20 min [60 mb], 30 min 
[90 mb]). When the maximum size is reached, video 
recording is automatically stopped. Videos should be 
downloaded using “Airtraq Cam”. It compresses videos, 
reducing its size but without losing resolution. 
9. PAEDIATRIC MODE
Press when using a paediatric Airtraq model. A message 
indicating “Paediatric mode” will appear in the lower area of 
the screen.
low-level disinfection between each patient use. Be sure to 
follow your institution’s specific cleaning procedures in 
consultation with this manual. 
1. Remove A-390 from the Airtraq and turn it off. 
2. Cleaning: Use clean cotton gauze pads that are saturated 
with the cleaning solution to wipe down the exterior surfaces 
of the A-390. Use soft brushes with the cleaning solution to 
remove any residues from areas that cannot be reached with 
the gauze pads. Be sure to remove all visible contaminant or 
foreign matter. Be careful to keep running liquid off the 
surfaces. The following cleaning solutions may be used:
a. Enzymatic Cleaning Solutions (e.g.: ENZOL
TM
Enzymatic Detergent).
b. Neutral pH soap and water.
c. Sodium bicarbonate solution (8- 10 %).
3. The following disinfection agents may be used:
a. Peracetic Acid Solution (0.08%).
b. Isopropyl Alcohol (70%).
c. Solution containing 70% Isopropyl Alcohol and 2% 
chlorhexidine (e.g. Clinell Wipe).
d. Solution containing chlorine dioxide (e.g. Tristel 
Wipe).
e. PDI Sani-Cloth® Germicidal Wipes (AF3, Bleach, Plus 
or Super Sani-Cloth
®
).
4. Blot dry the A-390 using an individual sterile surgical 
towel.
5. Silicone case can be cleaned using the following 
disinfection agents:
a. Isopropyl Alcohol (70%).
b. Solution containing 70% Isopropyl Alcohol and 2% 
chlorhexidine (e.g. Clinell Wipe).
Isopropyl alcohol can cause slight temporary swelling of the 
silicone, but as long as it is allowed to evaporate completely it 
will not deteriorate silicone case.
Caution: 
• Do not autoclave.
• Do not rinse under running water.
• Do not soak in liquids.
• Avoid liquid or moisture from going into the A-390.
• Avoid touching the lens of the A-390.
• Be careful with A-390 touch screen.
1. A-390 BASIC INFORMATION
Code: A-390 
Description: Airtraq Wi-Fi Camera
The A-390 has been specially designed to work only as an 
accessory for the Airtraq Video Laryngoscope. It is 
compatible with every Airtraq model.
The A-390 provides colour and real-time images on its 2.8 
inch integrated touch screen. 
Image can be rotated upside down when necessary.
The A-390 can record and playback videos which are stored 
on its internal memory. 
Videos can be downloaded to a PC (Windows or Mac) 
through a USB – Micro USB cable, using the application 
“Airtraq Cam”, available at www.airtraq.com (downloads 
section).
The A-390 can be connected via Wi-Fi to PC, tablet or 
smartphone according to IEEE 802.11 standard. A-390 does 
not use any existing Wi-Fi network but creates a proprietary 
one. An optional password guarantees that only authorized 
devices are allowed to receive video signal (follow your 
institution procedures and regulations if using these mobile 
devices). 
A-390 is powered by an internal rechargeable 3.7 V Li-Po 
battery and does not work when connected to a battery 
charger.
2. A-390 COMPONENTS
2.1. A-390 Camera
CMOS video camera with integrated touch screen and 
rechargeable Li-Po Battery.
2.2. USB - micro USB cable
To be used to connect the A-390 to a PC for video 
downloading or for camera’s settings administration.
2.3. Silicon protective case 
Provides additional protection against shocks.
It can be easily placed onto or removed from the camera.
2.3. Neoprene pouch 
Accessory to store A390 camera and USB cable 
A. Automatic power button: This button is automatically 
pushed when the A-390 is inserted onto any Airtraq. It can 
also be pushed manually to turn on the A-390. To turn off the 
A-390 press the corresponding icon on the menu. 
B. Battery charge connector: Brass surface connectors that 
connect to docking station for battery charge.
C. Micro USB female connector: to connect to PC or to battery 
charger.
4. A-390 BATTERY CHARGE & CHARGE STATUS CHECKING
The A-390 DOES NOT WORK WHEN IT IS BEING 
CHARGED. IT SHOULD BE CHARGED AT LEAST 1.8 M 
AWAY FROM THE PATIENT.
The A-390 is initially supplied with its battery discharged. It is 
recommended to perform a full charge/discharge cycle of the 
battery before starting to use the A-390 for clinical purposes.
After a full charge, the A-390 can operate for 240 minutes 
when Wi-Fi is deactivated and for 180 minutes when Wi-Fi is 
activated. Recharging takes approximately 110 minutes.
Without use, the battery will discharge at a rate of 1% per 
day.
If the A-390 can be turned on, then a minimum of 10 minutes 
of operating time is guaranteed.
When the A-390 is turned on, an icon and a figure will 
appear on the header of the screen showing battery charge 
status.
To charge battery: 
1. Connect the stand-alone battery charger to mains 
electrical supply.
2. Insert the micro USB connector to Docking Station and 
place A-390 onto it.
3. Alternatively, insert charger’s micro USB connector 
directly into the A-390. 
Upon starting to charge battery the A-390 will automatically 
turn Off. 
When battery is being charged the user can check charge 
status by touching the screen, which will show available 
minutes of operating time and a battery icon.
When in use, if the battery falls below 20 minutes of its 
capacity the battery charge indicator on the header of the 
message to the user and show an icon to cancel the shutdown 
process. If so, a new period of 30 minutes will start.
When A-390 is not assembled onto the Airtraq, and there is 
no action from the user for 5 minutes, A-390 will shut down 
automatically. Before turning off the screen will show a 
message to the user and show an icon to cancel the shutdown 
process. If so, a new period of 5 minutes will start.
7. TOUCH PANEL & MENUS
Press the action icons on the screen to select an action (touch 
panel also works when icons are pressed using gloves).
When in Live Video, pressing the Back Icon will make 
A-390 to return to the main menu.
Navigation is shown below:
20. OPERATING, STORAGE AND TRANSPORT
The A-390 should not be used, stored or transported at 
temperatures below -5 °C/23°F or over 55° C/131°F.
The relative humidity must not exceed 95%. The air pressure 
must not exceed 500 to 1060 hPa.
Please handle with care as with any other electronic device. 
Use the storage case provided to protect the device between 
each use. 
21. TECHNICAL DATA 
24.1. A-390 Camera
Electrical supply input ratings: 5 V DC, 1.5 A
Supply Voltage: Rechargeable Li-Po 3.7 V, 1400mAh.
Baseband Modulation – Wi-Fi - 802.11b: DSSS
Output RF Power: + 17.5 dBm Typ.
Transmission range: 5 m (approx.).
Screen: 2.8” TFT-LCD, 240 x 320 RGB.
Touch Panel: OGS type 2.8” Projected Capacitive Touch 
Panel.
Video Sensor: Digital CMOS video sensor, VGA 640 x 480.
Video resolution: 240x240.
Dimensions: 61 mm x 91 mm x 64 mm.
Weight: 110 grams.
24.2. Stand-alone Battery Charger
Electrical supply input ratings: 100-240 V ~, 50-60 Hz, 
0.1-0.2 A
EMC: EN55024, EN55022/B, EN 60601-1-2.
UL recognized component. Valid for the USA and Canada.
Micro USB type B male connector.
Cable length: 1,8 m.
22. REGULATORY
This device meets the requirements of European Medical 
Devices Directive 93/42/EEC of 14 June 1993.
The Declaration of Conformity (DoC) is available from the 
manufacturer.
This wireless emitter is in compliance with the essential 
requirements and other relevant provisions of Directive 
1999/5/EC.
This device complies with the Harmonized European Standard 
EN 301 489-17.
This device is in compliance with the RoHS European 
Directive.
IEC 60601-1 and IEC 60601-1-2 NOTICES AND WARNINGS
This device is specified as Internally Powered equipment, 
accessory, type BF Applied Part, IPXO, ordinary equipment, 
not intended for use with flammable agents, continuous 
operation. 
This product complies with IEC 60601-1 and IEC 60601-1-2 
International Standards for Medical Electrical Equipment.
According to IEC 60601 Standard A-390 together with 
Airtraq Laryngoscope comprise a Medical Electrical System. It 
complies with requirements regarding Electromagnetic 
Compatibility. Detailed results of Emissions and Immunity Tests 
are available from the manufacturer.
A-390 is a portable RF communications equipment and can 
affect Medical Electrical Equipment.
This equipment is intended for use by healthcare professionals 
only. This equipment may cause radio interference or may 
disrupt the operation of nearby equipment. It may be 
necessary to take mitigation measures, such as, reorienting or 
relocating the A-390.
This device shall only be used with cables and accessories 
provided by the manufacturer. Using other cables or 
accessories may result in increased emissions or decreased 
immunity of the ME System.
This device is classified as Internally Powered equipment 
powered by 3.7 V rechargeable battery for protection against 
electric shock.
The A-390 is classified as BF Applied Part.
This device is classified as IPX0, ordinary equipment, for 
degree of protection against ingress of water, as per IEC 
60529 International Standard (Degrees of Protection provided 
by enclosures).
No sterile parts.
Mode of operation continuous.
This device has non-ionizing radiation.
FCC AND INDUSTRY CANADA NOTICES AND WARNINGS
FCC COMPLIANCE:
Statement according to FCC part 15.19.
This device complies with part 15 of the FCC Rules. Operation 
is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may 
cause undesired operation.
Statement according to FCC part 15.21.
Changes or modifications not expressly approved by the party 
responsible for compliance could void the user’s authority to 
operate the equipment.
Statement for Class B digital device according to FCC part 
15.105.
NOTE: This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to part 15 
of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and 
can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to 
try to correct the interference by one or more of the following 
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and 
receiver.
• Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician 
for help.
INDUSTRY CANADA COMPLIANCE
Statement according to RSS Gen Issue 3, Sect.7.1.3.
This device complies with Industry Canada license-exempt RSS 
standard(s). Operation is subject to the following two 
conditions: (1) this device may not cause interference, and (2) 
this device must accept any interference, including 
interference that may cause undesired operation of the device.
Cet appareil est conforme aux normes CNR exemptes de 
licence d’Industrie Canada. Le fonctionnement est soumis aux 
deus conditions suivantes: (1) cet appareil ne doit pas 
provoquer d’interférences et (2) cet appareil doit accepter 
toute interférence, y compris celles susceptibles de provoquer 
un fonctionnement non souhaite de l’appareil.
Statement according to ICES.
This ISM device complies with Canadian ICES-001. Cet 
appareil ISM est conforme à la norme NMB-001 du 
Canada.
Caution: Changes or modifications not expressly approved 
by the party responsible for compliance could void the user’s 
authority to operate the equipment.
Avertissement: Tout changement ou toute modification non 
expressément approuvée par la partie responsable de la 
conformité pourrait annuler l'autorité de l'utilisateur pour 
faire fonctionner l’équipement.
23. DISPOSAL INSTRUCTIONS
Follow local governing ordinances and recycling plans 
regarding disposal or recycling of device components.
24. MANUFACTURER’S WARRANTY
Warranty & Service
The manufacturer warrants this device against faulty 
materials or manufacturing defects for a period of one (1) 
year from the date of purchase, provided that it is used in 
accordance with the procedures set up in the instructions for 
use. This warranty is only applicable if the device has been 
bought from an authorized distributor.
The manufacturer disclaims all other warranties, whether 
expressed or implied, including, without limitation the 
warranties of merchantability or fitness for a particular 
purpose.
The warranty covers free repair or swap for an equivalent 
device of a defective device which fault is proven to be 
consequence of the manufacturing process.
If you have any technical problems with the device, please 
call the Airtraq Distributor in your country or send a message 
through our web site (www.airtraq.com). Before making your 
call please have the serial number ready. The serial number 
of the A-390 is located on a sticker near the lens of the 
camera and also on the original package.
In case of a hardware defect confirming the warranty 
conditions, your device will be collected and you will receive 
another one within 20 working days after we receive your 
defective one.
Handling Instructions for Defective Devices
1. Return units must be packed in original and secured 
packaging materials. All accessories of the device (charger, 
cables, connectors, etc.) have to be sent back. Damaged 
incurred during transportation from the customer site is 
solely the responsibility of the sender. 
2. Customer must provide a contact name, phone number, 
shipping address, the serial number of the A-390, 
description of the problem and proof of purchase.
3. In all cases when the device shows defects which are not 
covered by the warranty, the customer will remain 
responsible for all handling costs and transportation fees.
Exclusions from Warranty
1. Product, where the serial number has been defaced, 
modified or removed.
2. Damage, deterioration or malfunction resulting from: 
A. Accident.
B. Misuse, neglect, fire, water, lightning or other acts of 
nature.
C. Repair or attempted repair by anyone not authorized by 
Supplier.
D. Modification by anyone not authorized by Supplier.
E. Any damage of the product due to shipment.
F. Causes external to the product, such as: over powering 
the unit, electric power fluctuations or failure, pouring 
liquids over the device, etc.
G. Normal wear and tear.
H. Any other causes which does not relate to a product 
defect.
25. IMPORTANT SAFETY INSTRUCTIONS
1. Keep, read and follow all of these instructions.
2. Heed all warnings in these instructions.
3. The A-390 does not work when it is being charged. It 
should be charged at least 1.8 m away from the patient.
4. Use only the A-390´s battery charger supplied by the 
manufacturer.
5. A-390 is portable RF communications equipment. It may 
cause radio interference or may disrupt the operation of 
nearby equipment. It may be necessary to take mitigation 
measures, such as, reorienting or relocating the A-390.
6. To reduce the risk of fire or shock hazard, do not expose 
this equipment to rain or moisture.
7. Do not charge near any heat source such as radiators, 
heat registers, stoves or other apparatus that produces heat.
8. Protect the charging cord from being damaged.
9. Do not use this equipment in presence of flammable 
anaesthetics.
10. ESD (Electrostatic discharge) may cause malfunction of 
these devices.
11. Unplug this apparatus during lightning storms or when 
unused for long periods of time.
12. Do not place vessels containing liquids on top of the 
apparatus. Do not splash liquids on top of the device.
13. Do not attempt to service these devices yourself as 
opening or removing covers may expose you to hazards. 
Refer all servicing to qualified service personnel from your 
Airtraq distributor.
Manufactured by: 
PRODOL MEDITEC LIMITED
No. 18, 7th Science Ave.,
Hi-Tec Coast, Zhuhai, 
Guangdong
519085 P.R. China
EU Representative:
PRODOL MEDITEC, S.A.
Muelle Tomás Olavarri 5, 
3º 48930 Las Arenas 
(Vizcaya). 
SPAIN
USA & Canada Representative:
AIRTRAQ LLC
2414 Lawton Ln.
Rowlet, TX 75089, USA
For further advice on using the A-390 visit www.airtraq.com 
or contact:
USA & Canada:  +1877-624-7929 
info.usa@airtraq.com
EU & Other:  +34944804690 
info@airtraq.com
Airtraq is a registered trademark.
Apple and the Apple logo, iPad and iPhone are trademarks 
of Apple Inc., registered in the U.S. and other countries. App 
StoreSM is a service mark of Apple Inc.
Android and Google PlayTM are trademarks of Google Inc.
Wi-Fi and the Wi-Fi logo are registered trademarks of the 
Wi-Fi Alliance.
All other trademarks and copyrights are the property of their 
respective owners.