User's Manual
AirSynergy 2000 Installation Guide
Page 58 Commercial in Confidence UGD-D01001 Rev A
Figure 61 - back plate straps
Figure 62 - back to back mounted with 4 straps
Mount the assembly on the universal mounting bracket and secure the flange nuts. The GPS
antenna and front mount antenna (if applicable) can be installed before or after mounting to the
pole depending on ease of access.
In cases where no front mount antenna is installed, an extended sun shield is available as an
accessory item and should be installed. The installation method is the same as the standard sun
shield with 3 fastenings on each side of the front AirSynergy unit.
Follow the normal procedures for the connection of power supply units and drop cabling to each
of the back to back mounted AirSynergy units.
Caution: When securing a back to back assembly to the mounting plate a safety
line should be secured to the units. The 6mm threaded holes used for the
protection ground at the bottom or the GPS mountings at the top of each Synergy
unit provide strong anchor points for a safety line. (This is the same threaded
hole used for protection ground connection in exposed areas or high lightening
risk areas).