User's Manual

AirSynergy 2000 Installation Guide
Page 50 Commercial in Confidence UGD-D01001 Rev A
Figure 51 - Mgmt IP Config
Note:
Dynamic” IP Allocation is not supported in the current release. Please
select Static.
Internal Port configuration is not applicable to 16e BS and must not be
used. Configuration of the internal port may lead to management comms
failure.
Clicking the “Submit” your configuration is NOT implemented
immediately in the BS. The BS needs to be rebooted for the new
configuration to be applied.
8. Navigate to “Reboot” and click on “Yes” to reboot the BS.
Figure 52 - reboot confirmation
8.2 Automatic Discovery via Netspan
Set the BS discovery profile in Netspan.
The following section explains the steps to take for the automatic discovery of AirSynergy via
Netspan.
Modify BS IP
Choose Untagged or
Modify the BS
Management VLAN when
applicable
(Take care when changing
to a management VLAN
since communication from
a Laptop or PC without the
relevant 802.1Q NIC
capability and configuration
will be lost)