User's Manual

AirSynergy 2000 Installation Guide
Page 49 Commercial in Confidence UGD-D01001 Rev A
8 Initial WEB Configuration
To set AirSynergy base station Management IP & BSID via Web Page. This prepares the
equipment for connection to Netspan.
Verify that the Web browser with which you want to access the Web-based Management is active.
8.1 Initial configuration
To connect to AirSynergy via the WEB interface, perform the following:
Caution: The GPS antenna should be installed and attached before AirSynergy is
powered on.
Caution: Wait two minutes before performing other actions.
1. Apply power to the AirSynergy and connect the PC to the Ethernet port.
2. In a browser, open web page with BS address
IP address 192.168.0.100 (255.255.255.0) (AirSynergy default IP address).
3. Enter the default username and password:
Username = synergy
Password = synergy
4. Click Submit
5. For WiMAX 16e applications Navigate to “General” menu to specify the BS ID. (Format
xxxxxx:yyyyyy)
Where xxxxxx is reserved for the Operator ID and yyyyyy is a unique Hexadecimal
reference number within the network.
Figure 50 - General BS Configuration
6. Click Save
Notes: iBridge Term menu item is not applicable to 16e BS and must not be
used. Configuration of “RF Channels” may lead to failed installation (failed
commissioning and no discovery). TBD
7. Navigate to “Management” and modify the IP address according to your network.
Enter BS ID