User's Manual

AirSynergy 2000 Installation Guide
Page 42 Commercial in Confidence UGD-D01001 Rev A
6.2 Connecting RF Jumper Cables to External Antenna
1. Attach, connect and secure the RF cable between the external antenna and the
appropriate RF connection on the top of the unit.
Figure 29 - Connecting RF cable
Caution: Do not over-tighten the RF connector. RF failures can result when the
RF connector is over-tightened.
Figure 30 - weather-proof the connection - front mount antenna
2. Weather-proofing of the RF N type connections is recommended. This is done with a
layer of self-amalgamating tape followed by an over layer of PVC tape.
3. Verify the RF connector is completely weather-sealed.
6.3 Connecting the Power Drop Cable to AirSynergy
1. Plan the position of the power drop cable run from the AirSynergy unit to the power
supply. The recommended maximum run length is 30m (98.44 ft). (For run lengths
greater than 30m please contact your Airspan representative)
2. Uncoil the cable and secure the connector just below the AirSynergy unit.
Note: When securing the cable make sure there is not tension on the connector
so that it is easy to disconnect and re-connect for future maintenance actions.
3. Position the pins correctly, the connector is secured to the unit with a locking ring that is
screwed into place. Use firm hand pressure only, the connector has a built in sealing ring.
Caution: The internal plastic parts of the mating connector are keyed. Take care
to align these by visual inspection or by gently rotating the connector body until
the key way sections align and the pins go in before tightening the locking ring.