MacroMAXe Installation Guide
Page 47 Commercial in Confidence UGD-D00181 Rev E
8 Appendix A
8.1 Review Job Sheet
The Job Sheet should include the following information:
¾ BS location and identity.
¾ Whether the system is required to be locked to a GPS timing reference.
¾ A BSID is required for each BS TRx. This should be in a format xxxxxx:xxxxxx where x is a
decimal digit.
¾ Network configuration information for the BS TRx.
Traffic Port: Not applicable.
IP Address: Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
Netmask: Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
Default Gateway: Should only be set if Management IP Mode is set to Static IP Address.
See below for Management IP Mode parameter.
Management VLAN: Specified as either Untagged or Tagged
Management VLAN Tag: Should only be set if Management VLAN is set to Tagged
Management IP Mode: Specified as Static IP Address or Obtain IP Address via DHCP
Ethernet Mode: Specified as Auto-negotiate or Fixed
Ethernet Rate: Need only be configured if Ethernet Mode is set to Fixed, specified as
10M or 100M.
Ethernet Duplex: Need only be configured if Ethernet Mode is set to Fixed, specified as
Full or Half.
¾ SNMP configuration information. This will allow events from the BS to arrive at the
specified Netspan server. This will include the following information:
Read Only Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under Server on Netspan left hand panel).
Read Write Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
SNMP Port Number: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
IP Address: This specifies Netspan IP address (found under Server Global
Configuration, which is under Server on Netspan left hand panel).
Community: Normally specified to the same value as for Read Only Community.
Port Number: Normally specified to a value of 9023.
¾
Whether the Primary Master or the Secondary Master manages the GPS module.
¾ NTP configuration. This specifies a list of NTP servers.