Page 50 Commercial in Confidence UGD-D00181 Rev G
Figure 34 - mounting bracket (2 required)
5.8.1 Junction Box Installation
To install the junction box:
1. Prior to installation connect the 2 mounting brackets to the back of the junction box
fastening to the provided holes. The wall mounting hole orientation should be towards the
outer edges of the junction box.
2. Remove the junction box‟s cover, leaving the rubber gasket in place.
3. Prepare the cables for connection by performing the following:
a. Strip about 25.4 mm (1 inch) of the outer jacket of the cable to expose the wires.
b. Using a wire-stripping tool, expose about 6.3 mm (0.25 inch) of each of the wires by
stripping the wires‟ insulation.
4. Determine which cable entry holes are to be used and remove the appropriate plug.
Table 19 - Cable hole sizes
Cable Entry hole determination
Gland hole PG11 (M18) for cable terminating at MicroMAXe
Gland hole PG29 (M36) for cable 12AWG x6
Gland hole PG16 (M22) for cable 14AWG x2
Note: Save the rubber grommets from the plugs to be used on the weatherproof
glands (connectors).
5. Remove the nut on the weatherproof connector and slide the rubber grommet onto the
threaded shaft.
6. Set the weatherproof connector into the hole and from inside the box, thread the included
nut onto the shaft until tight.
7. Insert the exposed wires into the relevant screw-type terminal block (+ to + and – to –)
and then secure them in place by tightening the screw of each terminal.
8. Fasten the Junction box onto the pole or wall as required within the required distance of
the Air4G-W24 enclosure.
9. Perform the same procedure (steps 3-7) with the cable terminating in the in the Air4G-
W24 enclosure.