User Manual

Air4G Installation Guide
Page 35 Commercial in Confidence UGD-D00181 Rev G
Figure 11 Pole Mounted Air4G
To mount the Air4G in the pole mount configuration (for poles 60 > 120 mm), perform the
following steps:
1. Attach the two (2) pole brackets (shown above in Table 6) to the pole (with the threaded holes
facing up) at the heights required to attach the Air4G.
2. Tighten upper pole bracket and hand tighten (loosely) the lower pole bracket for later
adjustment.
Caution: These units weigh 17 kg 17.6 kg, take care when lifting.
3. Lift and align the Air4G unit and place the screws through the head clearance holes and
position the unit so that the top mounting holes retain the unit and loosely tighten all screws.
4. Tighten all fixing screws.
5.2 Wall mount configuration
The following image shows the wall mount assembly.
Figure 12 Wall Mounted Air4G