User Manual

Air4G Installation Guide
Page 28 Commercial in Confidence UGD-D00181 Rev G
Air4G Base Station parts
Consisting of
Outdoor power converter for 3.xGHz
Type-IC DC Power Cable
Available either in - 10, 15 or 30 meter lengths. Additional lengths
available.
ODC Twin Fiber Cable
(Multimode) (optional)
(ordered separately)
Available either in - 10, 15, 30, 50, 75 or 100 meter lengths.
Note: Maximum up to 500 meters as this is a
multimode interface.
Multimode fiber pigtail
cable (not included)
(optional) (ordered
separately)
Multimode fiber pigtail cable ODC - LC connector. Terminates the
outdoor fiber cable and provides an indoor LC connector. 2 meter
length.
Grounding Cable
(required) (not included)
Circular earth braid, 120A current (16 mm²), jacketed or not with cable
size = AWG 4 6 with lug (terminal) on enclosure side with hole M6
The Air4G power supply (PS) can be installed with various cable lengths according to the site
requirements. The cable lengths are determined by the length of the run between the PS and the
Air4G. Use the following table to determine the required power supply output to ensure proper
operation of the Air4G.
Table 10 - Input Power for Air4G
Air4G 2x10
(2.3-2.7 GHZ)
&
Air4G 0707
(698-746 MHz)
Air4G 3x05
(3.3-3.38 GHZ)
Input Voltage to Air4G (1)
-38 VDC to -60 VDC
-38 VDC to -60 VDC
PS output Voltage 30 meter cable
(2)
-42 VDC min
-41 VDC min
PS output Voltage 75 meter cable
(2)
-50 VDC min
-46 VDC min
PS output Voltage 100 meter
cable (2)
-53 VDC min
-49 VDC min
Figure 4 - PS Air4G