User's Manual

Air4G-W24 Installation Guide
Page 64 Commercial in Confidence UGD-D00181 Rev G
9 Appendix A
9.1 Review Job Sheet
The Job Sheet should include the following information:
BS location and identity.
Whether the system is required to be locked to a GPS timing reference.
A BSID is required for each BS TRx. This should be in a format xxxxxx:xxxxxx
where x is a decimal digit.
Network configuration information for the BS TRx.
Traffic Port: Not applicable.
IP Address: Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
Netmask: Should only be set if Management IP Mode is set to Static IP Address. See
below for Management IP Mode parameter.
Default Gateway: Should only be set if Management IP Mode is set to Static IP Address.
See below for Management IP Mode parameter.
Management VLAN: Specified as either Untagged or Tagged
Management VLAN Tag: Should only be set if Management VLAN is set to Tagged
Management IP Mode: Specified as Static IP Address or Obtain IP Address via DHCP
Ethernet Mode: Specified as Auto-negotiate or Fixed
Ethernet Rate: Need only be configured if Ethernet Mode is set to Fixed, specified as
10M or 100M.
Ethernet Duplex: Need only be configured if Ethernet Mode is set to Fixed, specified as
Full or Half.
SNMP configuration information. This will allow events from the BS to arrive at the
specified Netspan server. This will include the following information:
Read Only Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under Server on Netspan left hand panel).
Read Write Community: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
SNMP Port Number: This should be specified to the same value as in Netspan
Discovery Parameters (found under "Server" on Netspan left hand panel).
IP Address: This specifies Netspan IP address (found under Server Global
Configuration, which is under Server on Netspan left hand panel).
Community: Normally specified to the same value as for Read Only Community.
Port Number: Normally specified to a value of 9023.
NTP configuration. This specifies a list of NTP servers.
9.2 Securing Fiber-optic Cable
The Milli-Tie can be used to secure cables in the same manner as normally used for nylon straps.
The steps below show the basic use of the product.
Caution: Over-tightening of cable ties may causes damage and degrade system
performance.
To secure fiber-optic cables, perform the following steps:
1. Place the Millie-Tie around the target, and thread the tongue through the last large
aperture in the rearmost cell.