User's Manual
Air4G-W24 Installation Guide
Page 30 Commercial in Confidence UGD-D00181 Rev G
Air4G-W24
Base Station
parts
Consisting of
Filter (Cavity
filter) Kit (for
2.3 GHz
variant only)
(U.S.A. – WCS
market only)
2 x Cavity Filters – 141-00-148
4 x antenna cables – 689-000-47
The Air4G-W24 power supply (PS) can be installed with various cable lengths according to the
site requirements. The cable lengths are determined by the length of the run between the PS and
the Air4G-W24. Use the following table to determine the required power supply output to ensure
proper operation of the Air4G-W24.
Table 11 - Input Power for Air4G-W24
Air4G-W24 2x10
(2.3-2.7 GHZ)
&
Air4G-W24 0707
(698-746 MHz)
Air4G-W24 3x05
(3.3-3.38 GHZ)
Input Voltage to Air4G-W24 (1)
-38 VDC to -60 VDC
-38 VDC to -60 VDC
PS output Voltage – 30 meter cable
(2)
-42 VDC min
-41 VDC min
PS output Voltage – 75 meter cable
(2)
-50 VDC min
-46 VDC min
PS output Voltage – 100 meter
cable (2)
-53 VDC min
-49 VDC min
Figure 6 - PS – Air4G-W24