User Manual
Table Of Contents
- 1 About this Guide
- 2 System Overview
- 3 Installation Prerequisites
- 4 Physical Description
- 5 BSDU Description
- 6 GPSD Description
- 7 GPS Description
- 8 AC/DC Power Converter
- 9 Mounting the Base Station Radio (BSR)
- 10 Mounting the BSDU
- 11 Mounting the GPS
- 12 Mounting the AC/DC Power Converter
- 13 Cabling the BSR
- 14 Connecting the SDA-4S to the power supply
- 15 Connecting Power Cable for SDA-4SDC
- 16 Connecting BSDU to AC/DC Power converter
- 17 Lightning and Surge Protection
- 18 Connecting Third-Party External Antennas
- 19 Appendix
MicroMAX Hardware Installation User Guide
Page 98 Commercial in Confidence UWB-D00068 Rev J
19 Appendix
19.1 Environmental
Table34‐BSR&SDA
Environmental
ETS 300 019-1-1 19
92
Class
1.2
Environmental conditions: storage
ETS 300 019-1-2 19
92
Class
2.3
Environmental conditions: transport
ETS 019-1-3 19
92
Class
3.2
Environmental conditions: stationary
weather-protected
Operating Temperature -33° to +55° C for outdoor MicroMAX BSR
0 to +40° C for indoor SDA
Humidity 95% @ 40° C (non condensing)
Storage Temperatures -40 to 70° C ambient
EMC ETS EN 301 489-4
Safety IEC60950-1, EN60950-1, UL60950-1
Table35–BSDU
Environmental
ETS 3000 019 ETSI
EMC
EN 300 386-2 ETSII
FCC 47CFR 15
sub B
FCC
Safety
Underwriters
Laboratories (UL)
1950 USA
IEC 60950 International
EN 60950 ETSI
Operating temperature 0-50° C ambient
Storage temperature -40 to 70° C ambient
Operating Humidity 15-90% RH
Storage Humidity 5-95% RH
Table36‐GPSD
Environmental
Operating Temperature 0 to +40° C