User Manual

Table Of Contents
MicroMAX Hardware Installation User Guide
Page 75 Commercial in Confidence UWB-D00068 Rev J
¾ BSDU to DC power supply cable (supplied with the BSDU)
Figure58‐BSDUtoDCcable
16.2 Power Cable Assembly
In the BSDU Kit there are two polarized and genderless unassembled Anderson Powerpole
power connectors: red for positive connection and black for the negative connection.
Figure59‐Powerconnectors(AndersonPowerpole)
The power connectors consist of housing (hood and a contact pins). The contact pin is displayed
below:
Figure60‐Contactpin
16.3 Housing the Connectors
The power connectors are supplied unassembled. Therefore, you need to crimp the power wires
to the connector's contact pins, and then house them in the Powerpole hood.
Crimping the power wires to the connectors:
1. Insert the wire into the contact pin's barrel, and then, with a standard crimping tool crimp the
barrel tightly onto the wire (recommended 20AWG cable wire).
Figure61Crimped
2. Insert the contact into the hood with the contact's tongue pointing downwards and snap
into place. Ensure that the housing spring mates with the underside of the contact's tongue.
Figure 62 - Insertion