User Manual

Table Of Contents
MicroMAX Hardware Installation User Guide
Page 39 Commercial in Confidence UWB-D00068 Rev J
To wall mount the GPSD:
On the wall, mark the position of the two mounting hooks. The dimensions of the wall-mounting
hooks are displayed in the template below.
Figure15‐mountingtemplate
1. Drill holes for each hole that you marked in the step above.
2. Insert wall anchors (supplied) into each of the drilled holes.
3. Insert the 9-inch screws (supplied) into the wall anchors. Ensure at least 2 mm of the screw
is exposed to allow insertion into the GPSD mounting holes.
4. Hold the GPSD with both hands, and align the entrance to the two mounting hooks with the
screws. Slide the screws into the mounting hooks, by lowering the GPSD onto the screws.
Note: For safety, both mounting hooks must be utilized when mounting the
unit.
Note: The GPSD is supplied with a 1-metre AC power lead assembly.
Therefore, ensure the unit is mounted within reachable distance to the
customer's mains power outlet.
Note: The maximum cable run between GPSD and MicroMAX is 100 meters.
Therefore, ensure the unit is mounted within reachable distance.
6.5 GPSD Architecture
The figures below display a typical setup, using the GPSD, multiple BSR(s), multiple SDA-4S or
SDA-4SDC, “y” cable and the GPS antenna.
Note: Alternately you can use the supplied external antenna which is limited
to 5 meters long.