User Manual
MacroMAXe-4RX Installation Guide
Page 28 Commercial in Confidence UGD-D00181 Rev F2
MacroMAXe Base
Station parts
Consisting of
Outdoor power converter for 3.xGHz
Type-IC DC Power Cable
Available either in - 10, 15 or 30 meter lengths.
ODC Twin Fiber Cable
(Multimode) (optional)
(ordered separately)
Available either in - 10, 15, 30, 50, 75 or 100 meter lengths.
Note: Maximum up to 500 meters as this is a
multimode interface.
Multimode fiber pigtail
cable (not included)
(optional) (ordered
separately)
Multimode fiber pigtail cable – ODC - LC connector. Terminates the
outdoor fiber cable and provides an indoor LC connector. 2 meter
length.
Grounding Cable
(required) (not included)
Circular earth braid, 120A current (16 mm²), jacketed or not with cable
size = AWG 4 – 6 with lug (terminal) on enclosure side with hole M6
The MacroMAXe power supply (PS) can be installed with various cable lengths according to the site
requirements. The cable lengths are determined by the length of the run between the PS and the
MacroMAXe. Use the following table to determine the required power supply output to ensure proper
operation of the MacroMAXe.
Table 10 - Input Power for MacroMAXe
MacroMAXe 2x10
(2.3-2.7 GHZ)
&
MacroMAXe 0707
(698-746 MHz)
MacroMAXe 3x05
(3.3-3.38 GHZ)
Input Voltage to MacroMAXe (1)
-38 VDC to -60 VDC
-38 VDC to -60 VDC
PS output Voltage – 30 meter cable
(2)
-42 VDC min
-41 VDC min
PS output Voltage – 75 meter cable
(2)
-50 VDC min
-46 VDC min
PS output Voltage – 100 meter
cable (2)
-53 VDC min
-49 VDC min
Figure 4 - PS – MacroMAXe