User Manual

Table Of Contents
Air4G Installation Guide
Page 43 Commercial in Confidence UGD-D00229 Rev B
Figure 26 - Surge protector cable connections
6. Connect the Surge Protector to ground it using a AWG#6 cable (green jacket) to tower
grounding plate (installed on the tower below the BS). All the base stations and their
surge protectors should be grounded in the same way.
Note: The ground plate should be isolated from the tower and connected using
AWB#2 wire to the grounding bonding of the tower according to the local code.
5.4 Air4G Connections
The following diagram displays the connections on the bottom side of the Air4G.
The base station requires a secure ground connection. The cable should also be grounded to the
tower which is grounded at the tower base. A grounding screw fitted with a flat washer and lock
washer is provided on the bottom of the chassis clearly marked with the universal ground symbol
as shown below.
Figure 27 - Air4G connections (bottom)
Note: Previous versions had 3 RJ45 (Ethernet) connections.
5.5 Install Air4G Antennas
Use this procedure to install a linear dual slant antenna for the Air4G in the mast mount
configuration.