User's Manual

AirHarmony-4000 (Integrated Duplexers) Installation Guide
UGD-D01080 Airspan Commercial and Internal Use 36
5.5.1 Power Cable Preparation
Tip: It is good practice to label both ends of the cable to identify which AirHarmony-4000
unit it is connected to.
Tip: It is good practice to leave a spare loop of cable (approximately 0.5m). This will allow
for easier wiring and will allow the cable to be re-terminated if necessary in the future.
The power cable is connected to the AirHarmony-4000 connector (marked PWR) on the bottom
panel of the unit.
1. Prepare the connector by unscrewing the body, included in the AirHarmony-4000
package.
Figure 25: AC connector
Figure 26: AC Connector disassembled
2. Strip back and remove the outer sheath to expose the inner black, white and green
insulated wires to a length of 3 cm (1.18 in). Then strip back 6 mm (0.24 in) of the inner
core insulation.
Figure 27: Strip wire