User's Manual

AirHarmony-4000 (Integrated Duplexers) Installation Guide
UGD-D01080 Airspan Commercial and Internal Use 28
The following displays a close up of the Pin (stud) alignment.
Figure 14: Align Pins
2. Lean the bottom of the unit into the mounting plate until the six (6) holes are aligned
with the six (6) M8 clinch-nuts on the mounting plate. There are two (2) on the top, near
the mounting pins and two (2) on either side of the mounting plate for a total of six (6) .
3. Once aligned insert the supplied M8x20 Hex head bolt with a split washer and a flat
washer into each clinch-nut.
4. Check and tighten all six (6) M8x20 Hex head bolts.
The following displays the AirHarmony-4000 mounted on a wooden pole.
Figure 15: AirHarmony mounted on Wooden Pole