User's Manual

AirHarmony-4000 (Integrated Duplexers) Installation Guide
UGD-D01080 Airspan Commercial and Internal Use 24
4.2.2 Mounting on a Non-Wooden Pole
The following images show the pole mount assembly on a non-wooden pole.
Caution: Take care to install the Pole/Wall mounting plate in the correct orientation.
Verify that the mounting pins are facing upwards as shown below.
Figure 10: Pole/Wall mounting plate (w/o bolt)
1. Select the location on the pole to mount the AirHarmony-4000. You can attach the
AirHarmony-4000 to any pole from 1-7/8 to 16 inches (47.6 to 406.4 mm) in diameter.
2. Insert the clamp straps through the slots in the mounting plate passing them through
the pole clamps.
3. Insert the clamp bands by passing them through the slots in the mounting plate, in four
(4) places.
Note: The clamp bands are not supplied by Airspan and are the responsibility of the
installer. Clamp bands should not be wider than 15.5 mm in order to fit in the slots on
the mounting plate.
4. Tighten the clamp bands with large flat screwdriver.