AirHarmony-4000 Installation Guide Integrated Duplexers Part Number: UGD-D01080 System Release: 14.
© Copyright by Airspan Networks Inc., 2016. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Inc. rights in the aforesaid information.
Table of Contents Document Information ...................................................................................... 1 Abstract ................................................................................................................................. 1 Revision History ..................................................................................................................... 1 Warnings and Cautions ...................................................................................
AirHarmony-4000 (Integrated Duplexers) Installation Guide Customer Care Help Desk ................................................................................ 11 Airspan Encourages Comments .......................................................................................... 11 1 Introduction ................................................................................................. 12 1.1 AirHarmony-4000 ......................................................................................
AirHarmony-4000 (Integrated Duplexers) Installation Guide 5.3 Cable Connections ....................................................................................................... 32 5.3.1 Copper Ethernet Cable Assembly ................................................................................ 32 Hardware Requirements ........................................................................................................ 32 Assembly Instructions....................................................
AirHarmony-4000 (Integrated Duplexers) Installation Guide Figure 40: power cable assembly.......................................................................................................... 37 Figure 41: Connector on cable .............................................................................................................. 37 Figure 42: Plug pins ...............................................................................................................................
AirHarmony-4000 (Integrated Duplexers) Installation Guide Document Information Abstract This document details procedures for installing the Airspan’s AirHarmony-4000 INT, a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for qualified personnel with a working knowledge of LTE. Revision History Revision Details Date Rev 0.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Warnings and Cautions Human Exposure to Radio Frequencies The AirHarmony-4000 antennas should be operated from a minimum safe distance of 4.6m Radio Interference The AirHarmony generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Safety 1. Read this guide and follow all operating and safety instructions. 2. Keep all product information for future reference. 3. Static sensitive components inside - do not remove the lid or base: No user serviceable parts inside. 4. Position the power cord to avoid possible damage. 5. Do not place this product on or near a direct heat source, and avoid placing objects on the terminal. 6.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Warning Symbols The following symbols may be encountered during installation or troubleshooting. These warning symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters. Familiarize yourself with standard safety practices before continuing. Electro-Magnetic Radiation High Voltage Service Information Refer all repairs to qualified service personnel.
AirHarmony-4000 (Integrated Duplexers) Installation Guide - Lack of properly installed lightning protection equipment that can cause equipment failures from lightning induced currents. A lighting protection system provides a means by which the energy may enter earth without passing through and damaging parts of a structure.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Italiano: Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC. Nederlands: Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC. Norsk: Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC. Português: Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Maximum Output TX Power Table 1: AirHarmony--4000 B26 FCC Maximum Output TX Power Frequency Band FCC TX 851-869 MHz Antenna Gain EIRP 46.16 dBm 57.54 dBm 13.5 dBi Table 2: AirHarmony-4000 B26 ETSI Maximum Output TX Power Frequency Band ETSI TX 851-869 MHz 46 dBm Antenna Gain EIRP TBD dBm 13.5 dBi Caution: Do not set maximum output TX power to higher than local regulations.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Scenario #1 - The long switched beam antenna is mounted directly on the unit and connected via its two RF ports and the control port. The GPS antenna is either mounted on the top of the unit (if conditions allow) or mounted separately with approved lightning protection. Scenario #2 - The long switched beam antenna is mounted on the pole above the unit connected via its two RF ports and the control port.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Mount iRelay (if applicable) Connect to External Antenna (if applicable) Connect and manage cables Field Replacement of Filter Set (when required) Intended Audience This guide is intended for persons who are responsible for installing the AirHarmony-4000. These persons should have a working knowledge of the equipment. AirHarmony can be tightly integrated with Airspan’s iBridge and iRelay transport solutions.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Document Organization Chapter Contents Introduction Provides a comprehensive overview of AirHarmony-4000 and its installation. Getting Started Provides workflows for initial install and workflow. Verifying Prerequisites Lists the hardware, software, and client requirements for installation. AirHarmony-4000 Installation Describes how to install AirHarmony-4000. GPS Installation Describes how to install the GPS antenna.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e-mails to Customer Care Help Desk.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirHarmony-4000 with Integrated Duplexers a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for readers with LTE working knowledge. All information in this document is for general information only, and is subject for change without notice. 1.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Note: AirHarmony-4000 must be properly grounded according with NEC and other local safety code requirements.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 2 Getting Started 2.1 Workflow of Installation The Workflow to install the AirHarmony-4000 is displayed in the following diagram: Figure 3: Workflow Caution: Antennas must be connected and attached before AirHarmony-4000 is powered on.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 2.2 AirHarmony-4000 Installation Checklist Plan the installation of the AirHarmony-4000 by using the Installation Checklist, which you can find as a removable job aid in Appendix A for this guide. 3 Verifying Prerequisites Prior to installing the AirHarmony-4000, verify the required safety, power, tools, parts and components. This chapter includes the hardware, software, and client requirements for installation.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 3.2.2 Verify the Parts and Kits Note: Verify your order and requirements to ensure the correct unit type is being installed. Table 6. Parts & Kits Installation Kit / Part AirHarmony 4000 819 824 / 864 869 MHz (B26M), Connectorize d AirHarmony 4000 universal wall & pole mounting kit Part No. HAR40-CNU26M1-B06AP HAR40-U-PMK-1 Airspan N0.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Installation Kit / Part Full AXS SM Fiber Cable 7.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Table 7. Amperage Draw Duplex Tx Power at RF Port (dBm) Maximum Power Consumption (W) TDD-FC1 2 x 43 340 FDD 2 x 43 340 3.2.4 Panels The following figures display the AirHarmony-4000 bottom and top panels. The following displays the AirHarmony-4000’s bottom panel.
AirHarmony-4000 (Integrated Duplexers) Installation Guide The following displays the AirHarmony-4000’s top panel. Figure 5: AirHarmony-4000 Unit, Top panel 3.2.5 Physical Dimensions AirHarmony-4000 is in an all outdoor enclosure. Table 8: AirHarmony-4000 Physical Dimensions Variant Dimensions (H x W x D) AirHarmony-4000 631 x 236 x 267 mm / 24.8 x 9.3 x 10.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 3.2.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 4 Installing AirHarmony-4000 Install the AirHarmony-4000 eNodeB by pole/wall mount. AirHarmony-4000 is mounted on a pole or wall in close proximity to its external antenna (connectorized variant). Remove the AirHarmony from its packaging in preparation for mounting. Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4000 on pole or wall. 4.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 4.2.1 Mounting on a Wooden Pole The following images show the pole mount assembly on a wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. Figure 7: Pole/Wall mounting plate 1. Select the location on the pole to mount the AirHarmony-4000. You can attach the AirHarmony-4000 to any pole from 1-7/8 to 16 inches (47.6 to 406.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 8. Tighten the clamp bands with large flat screwdriver. Figure 8: Mounting plate on pole Figure 9: Through-bolt & Mounting plate Mounting plate is installed and ready for AirHarmony-4000 mounting.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 4.2.2 Mounting on a Non-Wooden Pole The following images show the pole mount assembly on a non-wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. Figure 10: Pole/Wall mounting plate (w/o bolt) 1. Select the location on the pole to mount the AirHarmony-4000. You can attach the AirHarmony-4000 to any pole from 1-7/8 to 16 inches (47.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Figure 11: Mounting plate mounted 4.2.3 Mounting on a Wall The following images show the wall mount assembly. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below. 1. Position mounting plate against the wall with mounting pins facing up. Be sure to position the wall mounting plate straight with level mounting to ensure the unit sits evenly. 2.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Figure 12: Mounting Plate on Wall UGD-D01080 Airspan Commercial and Internal Use 26
AirHarmony-4000 (Integrated Duplexers) Installation Guide 4.3 Securing AirHarmony-4000 to the Mounting Plate Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4000 on pole or wall. To mount AirHarmony-4000 to the mounting plate, perform the following: 1. Lift up the AirHarmony-4000 unit and hook the slotted holes onto the mounting pins (studs) on the top of the mounting plate.
AirHarmony-4000 (Integrated Duplexers) Installation Guide The following displays a close up of the Pin (stud) alignment. Figure 14: Align Pins 2. Lean the bottom of the unit into the mounting plate until the six (6) holes are aligned with the six (6) M8 clinch-nuts on the mounting plate. There are two (2) on the top, near the mounting pins and two (2) on either side of the mounting plate for a total of six (6) . 3.
AirHarmony-4000 (Integrated Duplexers) Installation Guide The following displays the AirHarmony-4000 mounted on a concrete pole.
AirHarmony-4000 (Integrated Duplexers) Installation Guide The following displays the AirHarmony-4000 being mounted on a wall.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 5 AirHarmony-4000 Connections This section describes Grounding procedure, cable preparation and connections and external antenna assembly. 5.1 Grounding The AirHarmony-4000 requires a secure ground connection. The ground cable should be connected with a grounding screw fitted with a flat washer and lock washer to the bottom of the chassis clearly marked with the universal ground symbol as shown below.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 2. Weather-proof the RF connections. Note: The above is also applicable for replacement assembly. 5.2.2 Weather-proofing the Antenna Connections Weather-proofing of all the connections is required. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weather-proofing is best done at this stage to give easier access to the connections.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 1. Remove the Gland connector by unscrewing the body from the AirHarmony-1000, using the (supplied) Gland wrench. 2. Pass the prepared Ethernet cable through the tail nut, gland seal, body and front seal of the connector casing as shown below. Do not tighten the tail nut. Figure 20: Ethernet Cable through connector 3. Seat the RJ45 connector plug securely into the body cavity of the AirHarmony-4000 4.
AirHarmony-4000 (Integrated Duplexers) Installation Guide been tested and approved by Airspan. Available from Airspan if required. 5.4.1 SFP Cable Connection Figure 21: LC duplex cable assembly 1. Remove the protective dust cap from the connector housing assembled on the unit. 2. Line up the SFP transceiver module with the port and slide it into the port. 3. Connect the cable connector onto the board connector. Figure 22: Cable connector hook up to the board connector 4.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Figure 23: Slide on inner housing Note: Check that there no space between the inner housing and mounting flange. Check and remove any debris that might interfere with the connection. 6. Slide the outer shell over the inner housing and turn the outer bayonet shell 1/4 turn clockwise, until it clicks into place. Figure 24: Slide over and click Note: The shell should be hand tightened only. Do NOT use tools to tighten the shell.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 5.5.1 Power Cable Preparation Tip: It is good practice to label both ends of the cable to identify which AirHarmony-4000 unit it is connected to. Tip: It is good practice to leave a spare loop of cable (approximately 0.5m). This will allow for easier wiring and will allow the cable to be re-terminated if necessary in the future. The power cable is connected to the AirHarmony-4000 connector (marked PWR) on the bottom panel of the unit. 1.
AirHarmony-4000 (Integrated Duplexers) Installation Guide 3. Thread the 3 wire (stranded 16AWG) cable through the tail nut, gland seal, body and rubber gasket of the connector casing as shown below. Do not tighten the tail nut. Figure 28: power cable assembly 4. Insert the stripped wire ends of the cable into the connector sleeves. Figure 29: Connector on cable 5. Secure the wire ends of the power cable into the head part of the connector, as shown below.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Figure 32: Attaching wires 6. Insert into connector, the by alignment pin determines the correct orientation. 7. Tighten the tail nut on to the body forcing the seal to compress around the power cable. Caution: Do not over tighten the connector or the tail nut. The nut should be tightened to a torque of no more than 3.3 Nm (2.43 lb-ft) max.
AirHarmony-4000 (Integrated Duplexers) Installation Guide A Job Sheet This job sheet enables the users to keep track of their installation. It covers all the prerequisites required for accomplishing the AirHarmony-4000 installation.
AirHarmony-4000 (Integrated Duplexers) Installation Guide B Abbreviations Term Expansion 3GPP 3rd Generation Partnership Project, responsible for LTE ABS Almost Blank Subframes ACS Adjacent Channel Selectivity is a measurement of a receiver's ability to process a desired signal while rejecting a strong signal in an adjacent frequency channel.
AirHarmony-4000 (Integrated Duplexers) Installation Guide Term Expansion MCS Modulation and Coding Scheme MME Mobility Management Entity is the key control-node for the LTE access-network.