AirHarmony-4400 Installation Guide External Cavity Filters Part Number: UGD-D01186 System Release: 15.
© Copyright by Airspan Networks Ltd., 2016-2016. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary, privileged and intended only for the recipient. As such, the information is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Ltd. rights in the aforesaid information.
Table of Contents Document Information ...................................................................................... 2 Abstract ................................................................................................................................. 2 Revision History ..................................................................................................................... 2 Warnings and Cautions ...................................................................................
AirHarmony-4400 (External Cavity Filters) Installation Guide About This Document ...................................................................................... 12 Purpose ............................................................................................................................... 12 Intended Audience .............................................................................................................. 12 Document Conventions.................................................
AirHarmony-4400 (External Cavity Filters) Installation Guide 4.4.2 Mounting on a Non-Wooden Pole .............................................................................. 37 4.4.3 Mounting on a Wall ..................................................................................................... 38 4.5 Securing AirHarmony-4400 to the Mounting Plate ..................................................... 40 5 AirHarmony-4400 Connections ..............................................................
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 15: External Filters' Set slots & fastenings ................................................................................. 29 Figure 16: Mounting External Filters' set on Sun-shield ....................................................................... 30 Figure 17: Opening cover ...................................................................................................................... 30 Figure 18. Cover opened ...........
AirHarmony-4400 (External Cavity Filters) Installation Guide Table 6: Typographic Conventions ........................................................................................................ 12 Table 7. Minimum Hardware Requirements ........................................................................................ 18 Table 8. Parts & Kits .............................................................................................................................. 19 Table 9. Amperage Draw....
AirHarmony-4400 (External Cavity Filters) Installation Guide Document Information Abstract This document details procedures for installing the Airspan’s AirHarmony-4400 EXT, a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for qualified personnel with a working knowledge of LTE. Revision History Revision Details Date Rev 0.
AirHarmony-4400 (External Cavity Filters) Installation Guide Warnings and Cautions Human Exposure to Radio Frequencies The AirHarmony-4400 antennas should be operated from a minimum safe distance of 4.6m Radio Interference The AirHarmony generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
AirHarmony-4400 (External Cavity Filters) Installation Guide Son installation requiert une formation spécifique du personnel. L’AirHarmony-4400, radio et antenne doit être installe UNIQUEMENT par des installateurs professionnels expérimentés et ayant une connaissance des constructions locales et règles de sécurité, ainsi que, dès que nécessaire, disposant d’un agreement des autorités gouvernementales de régulation.
AirHarmony-4400 (External Cavity Filters) Installation Guide Securite 1. Lire attentivement ce guide et suivre les instructions d’utilisation et de sécurité. 2. Des composants sensibles a électricité statique sont utilisés à l’intérieur. Ne pas retirer le coffre ou la base. Aucune pièce a l’intérieur est d’utilité pour l’utilisateur. 3. La connexion "terre" doit être effectuée en priorité et avant d'effectuer les connexions à la source d'alimentation (phase et neutre). 4.
AirHarmony-4400 (External Cavity Filters) Installation Guide Sur les portions de réseau électrique de type courant continu (CC), un circuit basse impédance peut causer de sérieux arcs électriques qui pourraient bruler ou endommager les yeux. Retirer bagues, anneaux, montres etc… afin d’éviter les court-circuit sur le réseau CC.
AirHarmony-4400 (External Cavity Filters) Installation Guide a. The terminal does not function after following the operating instructions outlined in this manual. b. The product has been dropped or the housing is damaged. Locate the serial number of the terminal and record this on your registration card for future reference. Also record the MAC address, located on the product sticker. UL Information - The equipment must be properly grounded according with NEC and other local safety code requirements.
AirHarmony-4400 (External Cavity Filters) Installation Guide - The AC wall outlet ground must be connected to the same grounding system as the eNodeB. Outdoor Ethernet Cabling - Ethernet cable connected to should be outdoor grade with UV protection. - Use shielded out CAT5e (minimum) cabled terminated with metallic RJ45 connectors. - In order to protect the indoor unit, install surge protection circuits on all copper cables on their entrance to the building.
AirHarmony-4400 (External Cavity Filters) Installation Guide Suomalainen: Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen. Svenska: Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC. Român: Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei 1999/5/CE.
AirHarmony-4400 (External Cavity Filters) Installation Guide Table 3: AirHarmony-4400DL B41 Low Band FCC Maximum Output TX Total Power Frequency Band 2496 – 2568 MHz FCC TX Antenna Gain EIRP 46.20 dBm 64.20 dBm 18dBi Table 4: AirHarmony-4400 ETSI Maximum Output TX Total Power Frequency Band 2496 – 2690 MHz ETSI TX Antenna Gain EIRP 46 dBm 64 dBm 18dBi Caution: Do not set maximum output TX power to higher than local regulations.
AirHarmony-4400 (External Cavity Filters) Installation Guide External Antenna The externally mounted antenna should be a dual slant or cross polarized fixed antenna which are connected via two (2) DIN connectors located on the top panel or to the external Cavity filter. The antenna should be mounted to its appropriate mounting facility. Note: When utilized in conjunction with iRelay as backhaul maintain a vertical separation of at least 2 ft. (0.6 m).
AirHarmony-4400 (External Cavity Filters) Installation Guide About This Document Purpose This guide provides the workflow and step-by-step procedures for installing the Airspan’s AirHarmony-4400 Macro-class eNodeB variant.
AirHarmony-4400 (External Cavity Filters) Installation Guide Convention Element Caution Signifies a hazardous situation—if not avoided—can void the product warranty, and cause property damage. Describes how to avoid it. Important Provides necessary information to explain a task. Note Provides additional information. Tip Provides helpful hints. Document Organization Chapter Contents Introduction Provides a comprehensive overview of AirHarmony-4400 and its installation.
AirHarmony-4400 (External Cavity Filters) Installation Guide Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e-mails to Customer Care Help Desk.
AirHarmony-4400 (External Cavity Filters) Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirHarmony-4400 with external cavity filters a Macro-class eNodeB variant and its place in the Airspan product suite. This document is intended for readers with LTE working knowledge. All information in this document is for general information only, and is subject for change without notice. 1.
AirHarmony-4400 (External Cavity Filters) Installation Guide Note: AirHarmony-4400 must be properly grounded (16AWG minimum) according with NEC and other local safety code requirements. Warning: Required - circuit breaker for AC power source -16A for EU installation and 20A for US installation. Minimum – 10A. Figure 2: AirHarmony-4400 with Front & Rear Filter Sets & cover Note: External Filters set are sold separately and are installed on site by the customer.
AirHarmony-4400 (External Cavity Filters) Installation Guide 2 Getting Started 2.1 Workflow of Installation The Workflow to install the AirHarmony-4400 is displayed in the following diagram: Figure 3: Workflow Caution: Antennas and External filters must be connected and attached before AirHarmony-4400 is powered on.
AirHarmony-4400 (External Cavity Filters) Installation Guide 2.2 AirHarmony-4400 Installation Checklist Plan the installation of the AirHarmony-4400 by using the Installation Checklist, which you can find as a removable job aid in Appendix A for this guide. 3 Verifying Prerequisites Prior to installing the AirHarmony-4400, verify the required safety, power, tools, parts and components. This chapter includes the hardware, software, and client requirements for installation.
AirHarmony-4400 (External Cavity Filters) Installation Guide 3.2.2 Verify the Parts and Kits Note: Verify your order and requirements to ensure the correct unit type is being installed. Table 8. Parts & Kits Installation Kit / Part AirHarmony 4400 2500M Hz (B41) Part No. Airspan N0.
AirHarmony-4400 (External Cavity Filters) Installation Guide Installation Kit / Part Part No. Airspan N0. Consisting of: Image LSBA Control Cable Long SBA control cable AISG to AISG 1.5m Long SBA control cable AISG to AISG 3m Long SBA control cable AISG to AISG 5m Long SBA control cable AISG to AISG 10m Long SBA control cable AISG to AISG 16m CBLSBALCTRL1.
AirHarmony-4400 (External Cavity Filters) Installation Guide Installation Kit / Part Full AXS SM Fiber Cable 100m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 150m, Outdoor LC/DPX to LC, IP67 Full AXS SM Fiber Cable 200m, Outdoor LC/DPX to LC, IP67 Part No. FIB-FA100-LCSM-1 Airspan N0. 686-00-012 FIB-FA150-LCSM-1 686-00-013 FIB-FA200-LCSM-1 686-00-014 Consisting of: Image 3.2.
AirHarmony-4400 (External Cavity Filters) Installation Guide Table 9. Amperage Draw Duplex Tx Power at RF Port (dBm) Maximum Power Consumption (W) TDD-FC1 2 x 43 340 FDD 2 x 43 340 3.2.4 Panels The following figures display the AirHarmony-4400 bottom and top panels. The following displays the AirHarmony-4400’s bottom panel.
AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays the AirHarmony-4400’s top panel. Figure 5: AirHarmony-4400 Unit, Top panel 3.2.5 Physical Dimensions AirHarmony-4400 is in an all outdoor enclosure. Table 10: AirHarmony-4400 Physical Dimensions Variant Dimensions (H x W x D) AirHarmony-4400 509 x 262 x 252 mm / 20.0 x 10.3 x 9.9 inch Weight Main Unit (without filter sets) 19.6 Kg / 43.21 Lbs. Main Unit (with filter sets) 26 Kg / 57.32 Lbs.
AirHarmony-4400 (External Cavity Filters) Installation Guide 3.2.
AirHarmony-4400 (External Cavity Filters) Installation Guide 4 Installing AirHarmony-4400 Install the AirHarmony-4400 eNodeB by pole/wall mount. AirHarmony-4400 is mounted on a pole or wall in close proximity to its external antenna (connectorized variant). Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4400 on pole or wall. 4.
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 7: Rear External Filters' Set Note: The Rear External Filters’ Set come assembled with the M5 pan head screws holding the external filters in place on the filter bridge. 7. Align the four screw slots in order to fit the rear external filters’ set in place. 8. Position the rear external filters’ set on the AirHarmony-4400 in position so the slots on the sides align with the M5 pan head screws on the unit’s back plate. 9.
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 9: Back Bracket Assembly 12. Slide the filter to align it with its RF connector and fit together, then tighten the connector. Figure 10: Fitting RF Connector Caution: Take care not to over tighten the RF connector. The connector nut should be tightened to a nominal torque of no more than 15 [N*m] (11.06 lb-ft). Using either 22 mm or 7/8” open end torque wrench. 13.
AirHarmony-4400 (External Cavity Filters) Installation Guide 14. Next tighten the four (4) M8X20 Hex head bolts which fasten the filter to the filter bridge bracket. Figure 12: Tighten Hex Head Bolts Airspan recommends weather-proofing the RF connections. Note: Weather-proofing of all the connections is recommended. This is done with a layer of self-amalgamating tape followed by an over layer of PVC tape. The weather-proofing is best done at this stage to give easier access to the connections.
AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Take the front external filters’ set in preparation for assembly.
AirHarmony-4400 (External Cavity Filters) Installation Guide 4. Loosen the four (4) M5 screws on the Sun-Shield in order to fit the External Filters’ set in place. 5. Position the External Filters’ set on the AirHarmony-4400 in position on the Sun-Shield so the slots on the sides align with the M5 pan head screws projecting from the SunShield. Figure 16: Mounting External Filters' set on Sun-shield 6.
AirHarmony-4400 (External Cavity Filters) Installation Guide 8. Pull outward on the filter cover to pull it free and swing the filter cover down away from the cavity filters and open the cover completely. Figure 18. Cover opened 9. Slide the filter to align it with its RF connector and fit together, then tighten the connector. Caution: Take care not to over tighten the RF connector. The connector nut should be tightened to a nominal torque of no more than 15 [N*m] (11.06 lb-ft).
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 20: Tighten screws on filter 11. Slide the second filter to align it with its RF connector and fit together, then tighten the connector. Caution: Take care not to over tighten the RF connector. The connector nut should be tightened to a nominal torque of no more than 15 [N*m] (11.06 lb-ft). Using either 22mm or 7/8” open end torque wrench. Figure 21: Align and fit second filter to connector 12.
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 22: Tighten filter bridge screws on Sun-Shield 14. Swing the filters’ cover up till slots are aligned with the two (2) upper bolts on the filter bridge. 15. Once in place tighten all four (4) screws to lock the filters’ cover in place.
AirHarmony-4400 (External Cavity Filters) Installation Guide 1. 2. Unscrew the protective dust cap from the GPS antenna jack prior to mounting on the AirHarmony-4400. Align the GPS jack with the plug attached to the top panel on the AirHarmony-4400. Figure 24: Attaching GPS antenna to unit Caution: Take care not to over tighten so as not to damage the threads. Note: It is good practice to weather-proof all the antenna connections.
AirHarmony-4400 (External Cavity Filters) Installation Guide 4.4 Pole/Wall Mount Assembly Install the AirHarmony-4400 eNodeB by pole/wall mount. AirHarmony-4400 is mounted on a pole or wall in close proximity to its external antenna (connectorized variant). Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4400. 4.4.1 Mounting on a Wooden Pole The following images show the pole mount assembly on a wooden pole.
AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Drill a minimum 7/16” hole to accept the 3/8-16 threaded rod. 4. Thread the 3/8-16 threaded rod into the provided clinch-nut attached on the Pole/Wall mounting plate. 5. Holding the mounting plate (with the attached threaded rod) pass the 3/8-16 threaded rod through the drilled hole in the pole. 6. Install on the exposed thread that protrudes from pole a flat washer, split washer, and then a 3/8”-16 hex nut and tighten. 7.
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 27: Through-bolt & Mounting plate Mounting plate is installed and ready for AirHarmony-4400 mounting. 4.4.2 Mounting on a Non-Wooden Pole The following images show the pole mount assembly on a non-wooden pole. Caution: Take care to install the Pole/Wall mounting plate in the correct orientation. Verify that the mounting pins are facing upwards as shown below.
AirHarmony-4400 (External Cavity Filters) Installation Guide 1. Select the location on the pole to mount the AirHarmony-4400. You can attach the AirHarmony-4400 to any pole from 1-7/8 to 16 inches (47.6 to 406.4 mm) in diameter. 2. Insert the clamp straps through the slots in the mounting plate passing them through the pole clamps. 3. Insert the clamp bands by passing them through the slots in the mounting plate, in four (4) places.
AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Attach the mounting plate to the wall using Lag bolts (x8 recommended). Note: Lag bolts (x8) and necessary hardware are not supplied by Airspan and are the responsibility of the installer. Recommended minimum 5/16 x 4” dia. (8mm x 100mm) with appropriate plugs according to field conditions.
AirHarmony-4400 (External Cavity Filters) Installation Guide 4.5 Securing AirHarmony-4400 to the Mounting Plate Caution: Proper local rigging and hoisting practices should be followed when installing the AirHarmony-4400 on pole or wall. To mount AirHarmony-4400 to the mounting plate, perform the following: 1. Lift up the AirHarmony-4400 unit and hook the slotted holes onto the mounting pins (studs) on the top of the mounting plate.
AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays a close up of the Pin (stud) alignment. Figure 32: Align Pins 2. Lean the bottom of the unit into the mounting plate until the six (6) holes are aligned with the six (6) M8 clinch-nuts on the mounting plate. There are two (2) on the top, near the mounting pins and two (2) on either side of the mounting plate for a total of six (6) . 3.
AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays the AirHarmony-4400 mounted on a concrete pole.
AirHarmony-4400 (External Cavity Filters) Installation Guide The following displays the AirHarmony-4400 being mounted on a wall.
AirHarmony-4400 (External Cavity Filters) Installation Guide 5 AirHarmony-4400 Connections This section describes Grounding procedure, cable preparation and connections and external antenna assembly. 5.1 Grounding The AirHarmony-4400 requires a secure ground connection. The ground cable should be connected with the grounding screw (M6x16) fitted with a flat washer and lock washer (supplied) to the bottom of the chassis clearly marked with the universal ground symbol as shown below.
AirHarmony-4400 (External Cavity Filters) Installation Guide the filter, which has two (2) ports with DIN 4.1/9.5 connectors (Female - external thread) on the top of the cavity filter. Figure 37: DIN 4.1/9.5 connectors (external thread) Caution: Antennas must be connected and attached before AirHarmony is powered on. Caution: Power down AirHarmony prior to disconnecting antenna. 2. Weather-proof the RF connections. Note: The above is also applicable for replacement assembly. 5.2.
AirHarmony-4400 (External Cavity Filters) Installation Guide 5.3 Cable Connections Note: The following images are for illustration purposes only. The actual tools or hardware may differ according to manufacturer. 5.3.1 Copper Ethernet Cable Assembly The following demonstrates the recommended assembly instructions, hardware and tool requirements for the proper Ethernet cable assembly of the Ethernet Category 5e (enhanced) (CAT5e) cable used by Airspan products.
AirHarmony-4400 (External Cavity Filters) Installation Guide 3. Seat the RJ45 connector plug securely into the body cavity of the AirHarmony-4400 4. Tighten the Gland body into to the threaded hole on the bottom of the AirHarmony4400. 5. Tighten the tail nut on to the body using the included Gland wrench, forcing the seal compress around the cable. 6. Once the connector is properly installed, the cable should be positioned and secured to minimize stress on the cable. 5.
AirHarmony-4400 (External Cavity Filters) Installation Guide 4. Verify that the locking latch on the cable connector is engaged on the board connector. 5. Slide the inner housing and ground shield (if present) over the cable and over the molding. Figure 42: Slide on inner housing Note: Check that there no space between the inner housing and mounting flange. Check and remove any debris that might interfere with the connection. 6.
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 43: Slide over and click Note: The shell should be hand tightened only. Do NOT use tools to tighten the shell. Once the connector is properly installed, the cable should be positioned and secured to minimize stress on the cable and connector. 5.5 Connecting the AC Power Cable to AirHarmony-4400 Danger: Hazardous voltage! Before working, ensure that the power is removed from the power connection cables.
AirHarmony-4400 (External Cavity Filters) Installation Guide Figure 45: AC Connector disassembled 2. Strip back and remove the outer sheath to expose the inner black, white and green insulated wires to a length of 3 cm (1.18 in). Then strip back 6 mm (0.24 in) of the inner core insulation. Figure 46: Strip wire 3. Thread the 3 wire (stranded 18AWG) cable through the tail nut, gland seal, body and rubber gasket of the connector casing as shown below. Do not tighten the tail nut.
AirHarmony-4400 (External Cavity Filters) Installation Guide 5. Secure the wire ends of the power cable into the head part of the connector, as shown below. Figure 49: Plug pins Figure 50: Pin assignment Pin # Wire Color Description 1 White Neutral 2 Black Phase 3 Green Ground Figure 51: Attaching wires 6. Insert into connector, the by alignment pin determines the correct orientation. 7. Tighten the tail nut on to the body forcing the seal to compress around the power cable.
AirHarmony-4400 (External Cavity Filters) Installation Guide 8. Remove the connector’s protective cap on the bottom panel of the unit. 9. Slide the Connecter Clamp over the connector housing prior to connecting. Figure 52: Connector Clamp 10. Tighten the assembled power cable to the connector. Caution: The internal plastic parts of the mating connector are keyed.
AirHarmony-4400 (External Cavity Filters) Installation Guide 5.5.2 Securing Connector Clamp Warning: Required – For safety reasons it is imperative to secure the power cable with the Connector clamp after connection. This is to prevent manually disconnecting the power cable. After the power cable is connected securing the connection is required. 1. This is performed by inserting the 2 – M4 x 12 screws into the provided holes and tightening the screws.
AirHarmony-4400 (External Cavity Filters) Installation Guide A Job Sheet This job sheet enables the users to keep track of their installation. It covers all the prerequisites required for accomplishing the AirHarmony-4400 installation.
AirHarmony-4400 (External Cavity Filters) Installation Guide B Abbreviations Term Expansion 3GPP 3rd Generation Partnership Project, responsible for LTE ABS Almost Blank Subframes ACS Adjacent Channel Selectivity is a measurement of a receiver's ability to process a desired signal while rejecting a strong signal in an adjacent frequency channel.
AirHarmony-4400 (External Cavity Filters) Installation Guide Term Expansion MME Mobility Management Entity is the key control-node for the LTE access-network. It is responsible, among other things for idle mode UE tracking and paging procedure including retransmissions MTBF Mean Time Between Failures OFDMA Orthogonal Frequency-Division Multiple Access (OFDMA) is a multi-user version of OFDM digital modulation scheme, used for eNodeB transmissions to UEs PDCP Packet Data Convergence Protocol.