User's Manual
AirHarmony-1000D Installation Guide
UGD-D01083 Airspan Commercial and Internal Use 15
3 Verifying Prerequisites
Prior to installing the AirHarmony-1000D, verify the required safety, power, tools, parts and
components. This chapter includes the hardware, software, and client requirements for installation.
Important: Set up requirements for the installation is detailed in the Job Sheet, see Appendix A.
3.1 Verifying Site Requirements
To set up the AirHarmony-1000D, an IP connection to a Netspan server is required.
3.2 Verify Installation Requirements
3.2.1 Verify the Tools
Note: AirHarmony-1000D variants with front mounted, Sunshield (pending) and Switched Beam
(pending) antennas come pre-assembled from the production line.
Table 8. Minimum Hardware Requirements
Tool
Use
Large flat bladed screwdriver
securing the pole straps
10mm or 13/32 inch wrench
for securing flange nuts
Large pliers
Tightening cable glands - To fit 15mm
3.2.2 Power Supply
AirHarmony-1000D supports direct connection to DC power source (-48V DC):
Operational Voltage Range: -40.5 to -57 VDC
Transient Voltage: +150V (ETR283)
AC power feed is also available, using an AC/DC power converter offered by Airspan.