AirHarmony-1000D Installation Guide Part Number: UGD-D01083 System Release: 14.
© Copyright by Airspan Networks Inc., 2016. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Inc. rights in the aforesaid information.
Table of Contents Document Information.............................................................................1 Abstract .................................................................................................................. 1 Revision History ..................................................................................................... 1 Warnings and Cautions...........................................................................2 Human Exposure to Radio Frequencies .............
AirHarmony-1000D Installation Guide 1 Introduction ....................................................................................... 12 1.1 AirHarmony-1000D........................................................................................ 12 1.1.1 Deployment .................................................................................................. 12 2 Getting Started .................................................................................. 14 2.1 Workflow of Installation ....
AirHarmony-1000D Installation Guide A Job Sheet .......................................................................................... 37 B Abbreviations .................................................................................... 38 Figures Figure 1: AirHarmony-1000D with sun-shield ......................................................................................... 8 Figure 2: AirHarmony-1000D ..............................................................................................
AirHarmony-1000D Installation Guide Tables Table 1: AirHarmony-1000DF B41 Full Band FCC Maximum Output TX Power .................................. 7 Table 2: AirHarmony-1000DH B41 High Band FCC Maximum Output TX Power ................................ 7 Table 3: AirHarmony-1000DL B41 Low Band FCC Maximum Output TX Power .................................. 7 Table 4: AirHarmony-1000D ETSI Maximum Output TX Power ............................................................. 7 Table 5: Power Consumption .......
AirHarmony 1000D Installation Guide Document Information Abstract This document details procedures for installing the Airspan’s AirHarmony 1000D Micro eNodeB variant. Revision History Revision Details Date Rev 0.
AirHarmony-1000D Installation Guide Warnings and Cautions Human Exposure to Radio Frequencies The AirHarmony-1000D antennas should be installed and operated from a minimum safe distance of: AirHarmony-1000D with External Antenna: 2.5m AirHarmony-1000D with Smart Beam Antenna (SBA): 2.
AirHarmony-1000D Installation Guide 6. To avoid electrical shock do not install this device during adverse conditions such as rain or inclement weather. 7. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the power before cleaning. 8. The units should not be located too near power lines or other electrical power circuits, where it can come into contact with such power lines or circuits. 9.
AirHarmony-1000D Installation Guide a. The terminal does not function after following the operating instructions outlined in this manual. b. The product has been dropped or the housing is damaged. Locate the serial number of the terminal and record this on your registration card for future reference. Also record the MAC address, located on the product sticker. UL Information - The equipment must be properly grounded according with NEC and other local safety code requirements.
AirHarmony-1000D Installation Guide DECLARATION OF CONFORMITY European Community, Switzerland, Norway, Iceland, and Liechtenstein Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC English: This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Deutsch: Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie 1999/5/EU.
AirHarmony-1000D Installation Guide GPS Compliance The GPS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
AirHarmony-1000D Installation Guide Maximum Output TX Power Table 1: AirHarmony-1000DF B41 Full Band FCC Maximum Output TX Power Frequency Band FCC TX EIRP 2496 – 2690MHz 40.31dBm 58.31dBm Antenna Gain 18dBi Table 2: AirHarmony-1000DH B41 High Band FCC Maximum Output TX Power Frequency Band FCC TX EIRP 2618 – 2690MHz 40.61dBm 59.61dBm Antenna Gain 18dBi Table 3: AirHarmony-1000DL B41 Low Band FCC Maximum Output TX Power Frequency Band FCC TX EIRP 2496 – 2568MHz 40.36dBm 58.
AirHarmony-1000D Installation Guide Antenna System The following antennas are designed specifically for AirHarmony-1000 deployments. Externally mounted antennas are available for use as well (pending), but are specified separately. Note: For a list of compatible external antennas, please contact your nearest Airspan sales representative.
AirHarmony-1000D Installation Guide About This Document Purpose This guide provides the workflow and step-by-step procedures for Installing the AirHarmony-1000D. These procedures include: Verify prerequisites Install wall / pole mount Install the AirHarmony-1000D Connect and manage cables Intended Audience This guide is intended for persons who are responsible for installing the AirHarmony1000D equipment. These persons should have a working knowledge of the equipment.
AirHarmony-1000D Installation Guide Document Organization Chapter Contents Introduction Provides a comprehensive overview of AirHarmony 1000 and its installation. Getting Started Provides workflows for installation . Verifying Prerequisites Lists the hardware, software, and client requirements for installation. AirHarmony-1000D Installation Describes how to install AirHarmony-1000D. Connect and Manage Cables Describes how to connect the cables.
AirHarmony-1000D Installation Guide Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e-mails to Customer Care Help Desk.
AirHarmony-1000D Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirHarmony-1000D Micro / Pico eNodeB variant and its place in the Airspan product suite. 1.1 AirHarmony-1000D AirHarmony-1000D is part of Airspan’s carrier-class 4G Micro eNodeB family. AirHarmony-1000D supports 3GPP’s Long Term Evolution (LTE) eNodeB specifications, providing high-speed data and mobility in order to meet the demands of the Broadband Wireless Access market.
AirHarmony-1000D Installation Guide Figure 2: AirHarmony-1000D Note: The illustration above displays the GPS connected directly to the top of the unit; there is also a remote GPS antenna option.
AirHarmony-1000D Installation Guide 2 Getting Started 2.1 Workflow of Installation The Workflow to install the AirHarmony-1000D is shown in the following diagram: Figure 3: Workflow Caution: Antennas must be connected and attached before AirHarmony-1000D is powered on. 2.2 AirHarmony-1000D Installation Checklist Plan the installation of the AirHarmony-1000D by using the Installation Checklist, which you can find as a removable job aid in Appendix A for this guide.
AirHarmony-1000D Installation Guide 3 Verifying Prerequisites Prior to installing the AirHarmony-1000D, verify the required safety, power, tools, parts and components. This chapter includes the hardware, software, and client requirements for installation. Important: Set up requirements for the installation is detailed in the Job Sheet, see Appendix A. 3.1 Verifying Site Requirements To set up the AirHarmony-1000D, an IP connection to a Netspan server is required. 3.2 Verify Installation Requirements 3.2.
AirHarmony-1000D Installation Guide 3.2.3 Verify the Parts and Kits The following figures display various AirHarmony-1000D components and accessory kits. Note: Verify order and requirements to ensure the correct unit type is being installed. Table 9: AirHarmony-1000D Components Parts Description Installation Kit / Part Product Code AirHarmony 1000D 2.496 - 2.568 GHz (B41L), Connectorized, AC, Copper BH with PoE out HAR10D-CN-U41L-B00AP AirHarmony 1000D 2.618 - 2.
AirHarmony-1000D Installation Guide Parts Description Installation Kit / Part Product Code AC/DC Outdoor Power Converter Kit & hardware Wall & Pole mounting for AC/DC Converter Mounting bracket for AC/DC converter. Serratub Maxi Clamp, band 12mm wide + quick adjust lock, 50-215mm pole dia.
AirHarmony-1000D Installation Guide Parts Description Installation Kit / Part Product Code Images PWR-10-MF-1 DC Power cable v1, 10m Alternative to the AC/DC converter kit. Additional lengths available. PVC Insulation tape 20m, Black 19mm width Self-amalgamating waterproof tape 10m, Black 25mm width Finisar SFP Transceiver PVC-INS-TAPE-1 S-AMAL-WP-TAPE-1 Airspan Recommends: FTLF1318P3BTL 1000BASE-LX Tested and approved by Airspan. Available from Airspan if required.
AirHarmony-1000D Installation Guide Figure 5: AirHarmony-1000D Unit, Top, RF ports w/o Sun-Shield 3.2.4 Physical Dimensions AirHarmony-1000D is in an all outdoor enclosure. Table 10. AirHarmony-1000D Physical Dimensions Variant Dimensions (H x W x D) Comment Connectorized (with sunshield) SBA (with sunshield) 549 x 142 x 203 mm / 21.6 x 5.6 x 8.0 in. 770 x 142 x 203 mm / 30.3 x 5.6 x 8.0 in.
AirHarmony-1000D Installation Guide ETSI EN 300-019-1-2 Transportation Table 11.
AirHarmony-1000D Installation Guide 4 Before Installation of AirHarmony-1000D Prior to installation of the AirHarmony either on a pole or a wall the GPS antenna should be connected and the all antenna connections should be weather-proofed. 4.1 Connection of GPS Antenna The following defines the connection of the GPS antenna which is installed directly to the top of the unit. 1. Remove the protective dust cap from the GPS antenna jack prior to mounting on the AirHarmony-1000D. 2.
AirHarmony-1000D Installation Guide Figure 7: Verify connection of RF cable Caution: Do not over-tighten the RF connector. RF failures can result when the RF connector is over-tightened. Figure 8: Weather-proof the connection 2. Weather-proofing of the connections is mandatory. This is done with a layer of selfamalgamating tape followed by an over layer of PVC tape. Both the self-amalgamating tape and the PVC tape are available from Airspan. 3. Verify the RF connector is completely weather-proof.
AirHarmony-1000D Installation Guide 5 Installing AirHarmony-1000D Install the AirHarmony-1000D eNodeB by pole mount or wall mount. AirHarmony-1000D is mounted on a pole or wall with its pre-installed antenna (front mount or SBA variants (pending)) or in close proximity to its external antenna (connectorized variant). Take care to install the mounting plate the correct way up. This is with the slot openings in the bracket at the top edges as shown below.
AirHarmony-1000D Installation Guide Figure 10: Mounting plate on pole 3. Position mounting plate on the pole with slots facing up. 4. Feed clamp bands through the quick release locking mechanisms and wrap around pole. Figure 11: Assemble clamp bands (4 required) 5. Wrap the band to properly fit on the pole. Press down locking mechanism with band excess fed through the mechanism. Figure 12: Press down locking mechanism 6. Align and position each of the 4 pole clamps.
AirHarmony-1000D Installation Guide Figure 13: Tighten clamp bands 7. Mounting plate is installed and ready for AirHarmony-1000D mounting.
AirHarmony-1000D Installation Guide Figure 15: Mounted on pole 5.2 Wall Mount Assembly The following images show the wall mount assembly. 1. Position mounting plate against the wall with slots facing up. Be sure to position the wall mounting plate straight with level mounting to ensure the unit sits evenly.
AirHarmony-1000D Installation Guide Figure 16: Positioning wall mounting plate 2. Mark the wall through the holes on the wall mount at the required height. 3. Attach the mounting plate to the wall using wall plugs (x4) rated for at least 8-10 Kg per fastener. Figure 17: Wall mounting plate fastened on wall Note: Wall plugs (x4) and necessary hardware are not supplied by Airspan and are the responsibility of the installer. Recommended minimum 8mm dia.
AirHarmony-1000D Installation Guide 5.3 Securing AirHarmony-1000D to the Mounting Plate Note: The following procedure shown with the Front-Mount antenna variant as shown below. To mount AirHarmony-1000D to the mounting plate, perform the following: 1. Loosely fit the flange nuts on the studs protruding from the sides of the unit. Figure 18: Lift unit to top of mounting plate 2. Hook the studs into the top slots of the mounting plate. Figure 19: unit engages into slots on the top of mounting plate 3.
AirHarmony-1000D Installation Guide Figure 20: AirHarmony-1000D unit engaged into the bottom slots 4. Tighten the flange nuts (4 places) to the required degree of down-tilt. 5. Check and tighten all flange nuts. 5.4 LED Display A single tri-color LED (Green/Red/Orange) appears at the bottom of the unit, providing unit status indication.
AirHarmony-1000D Installation Guide Note: Prior to insertion apply No-Ox or other approved anti-oxidation agent. This ground cable should be connected to a protection ground bar or clamped directly to a steel structure. A direct earth ground connection is required for the surge protection devices inside the AirHarmony-1000D to be effective. 1. Remove grounding screw and slip the ring terminal end of the ground cable onto the screw prior to re-setting into the threaded hole.
AirHarmony-1000D Installation Guide 6 Cable Connections Hazardous voltage! Before working, ensure that the power is removed from the power connection cables. When the system is powered on, do not touch the power terminals. 6.1 Copper Ethernet Cable Assembly The following demonstrates the recommended assembly instructions, hardware and tool requirements for the proper Ethernet cable assembly of the Ethernet Category 5e (enhanced) (CAT5e) cable used by Airspan products.
AirHarmony-1000D Installation Guide 3. Seat the RJ45 connector plug securely into the body cavity of the AirHarmony-4000 4. Tighten the Gland body into to the threaded hole on the bottom of the AirHarmony-4000. 5. Tighten the tail nut on to the body using the included Gland wrench, forcing the seal compress around the cable. 6. Once the connector is properly installed, the cable should be positioned and secured to minimize stress on the cable. 6.
AirHarmony-1000D Installation Guide 4. Verify that the locking latch on the cable connector is engaged on the board connector. 5. Slide the inner housing and ground shield (if present) over the cable and over the molding. Figure 26: Slide on inner housing Note: Check that there no space between the inner housing and mounting flange. Check and remove any debris that might interfere with the connection. 6.
AirHarmony-1000D Installation Guide Figure 27: Slide over and click Note: The shell should be hand tightened only. Do NOT use tools to tighten the shell. 7. Once the connector is properly installed, the cable should be positioned and secured to minimize stress on the cable and connector. 6.3 Power Cable Preparation The Power cable is connected to the AirHarmony-1000D using a Gland connector assembled on the bottom panel of the unit. 1.
AirHarmony-1000D Installation Guide Figure 29: Power cable assembly Caution: Do not over tighten the gland connector or the tail nut. The gland nut should be tightened to a torque of no more than 3.3 Nm (2.43 lb-ft) max. Note: When securing the cable verify there is no tension on the connector so that it is easy to disconnect and re-connect for future maintenance actions. Figure 30: Attach Power cable Caution: The internal plastic parts of the mating connector are keyed.
AirHarmony-1000D Installation Guide 7 Additional Installations (Non-Standard) 7.1 Connecting RF Jumper Cables to External Antenna Note: Variants utilizing remotely attached antennas are factory pre-assembled with a sunshield. For installation of a remotely mounted antenna follow the antenna manufacturer’s instructions and connect the antenna to the AirHarmony-1000D using the appropriate cables. (Weather-proofed Ntype Heliax RF cables (ordered separately). 1.
AirHarmony-1000D Installation Guide A Job Sheet This job sheet enables the users to keep track of their installation. It covers all the prerequisites required for accomplishing the AirHarmony-1000D installation.
AirHarmony-1000D Installation Guide B Abbreviations Term Expansion 3GPP 3rd Generation Partnership Project, responsible for LTE ABS Almost Blank Subframe ACS AWGN Adjacent Channel Selectivity is a measurement of a receiver's ability to process a desired signal while rejecting a strong signal in an adjacent frequency channel.
AirHarmony-1000D Installation Guide LED Light Emitting Diode LTE Long Term Evolution MAC Medium Access Controller – responsible for several functions such Error Correction, Packet (De)Multiplexing, etc… MBSFN Multicast-Broadcast Single Frequency Network is an LTE feature designed to deliver services such as Mobile TV using the LTE infrastructure, and is expected to be a competitor to DVB-H-based TV broadcast MCS Modulation and Coding Scheme MME Mobility Management Entity is the key control-node f