AU540 eNB B41 User Guide Part Number: UGD-D01112 System Release: 15.
© Copyright by Airspan Networks Inc., 2016. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary, privileged and intended only for the recipient. As such, the information is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any specific agreements protecting Airspan Networks Ltd. rights in the aforesaid information.
Table of Contents Document Information.............................................................................2 Abstract .................................................................................................................. 2 Revision History ..................................................................................................... 2 Warnings and Cautions...........................................................................3 Human Exposure to Radio Frequencies .............
AU540 eNB B41 User Guide Customer Care Help Desk ....................................................................12 Airspan Encourages Comments .......................................................................... 12 1 Overview ........................................................................................... 13 1.1 Management ................................................................................................. 13 1.2 AU540 eNB B41 Block Diagram ..............................
AU540eNB Module User Guide UGD-D01083 Airspan Commercial and Internal Use 1
AU540 eNB B41 User Guide Document Information Abstract This document details a description of and initial configuration of Airspan’s AU540 eNB B41 (LTE) module. Revision History Revision Details Date 0.
AU540 eNB B41 User Guide Warnings and Cautions Human Exposure to Radio Frequencies The AU540 eNB B41 antennas should be installed with a minimum distance of 20 CM from your body. Radio Interference This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to internal vehicle radio communications. Please ensure a maximum separation between the AU540 eNB B41’s antenna and other antennas.
AU540 eNB B41 User Guide 4. Position the power cord to avoid possible damage; do not overload circuits. 5. Do not place this product on or near a direct heat source, and avoid placing objects on the terminal. 6. To avoid electrical shock do not install this device during adverse conditions such as rain or inclement weather. 7. Use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners. Disconnect the power before cleaning. 8.
AU540 eNB B41 User Guide Adherence to European Directive 1999/5/EC European Council Recommendation 1999/5/EC details basic restrictions and reference levels on human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these recommended restrictions and reference levels should provide a high level of protection as regards the established health effects that may result from exposure to electromagnetic fields.
AU540 eNB B41 User Guide UL Information - The circuit where the equipment is connected must be properly grounded according with NEC and other local safety code requirements. - Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as is practical.
AU540 eNB B41 User Guide Español: Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC. Greek: ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Airspan ΔΗΛΩΝΕΙ ΟΤΙ Ο ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ. Français: Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC.
AU540 eNB B41 User Guide particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
AU540 eNB B41 User Guide Maximum Output TX Total Power Table 1: AU540 eNB FCC Maximum Output TX Total Power Frequency Band (MHz) TX (dBm) EIRP (dBm) Antenna Gain (dBi) Variant 2506-2680 23.9 32.9 9 AU540 Caution: Do not set maximum output TX power to higher than local regulations. Power Consumption AU540 eNB B41 has a Max nominal power consumption of 24W.
AU540 eNB B41 User Guide Antenna Usage AU540 eNB B41 module has four (4) RF ports that are connected to two (2) dual-port antennas arrays. Each antenna array is mounted on opposite sides internally within the Airspan product housing. This is so that one antenna array faces forwards and one antenna array faces outwards for optimized coverage. Antenna Types There are internally mounted antennas connected to the AU540 eNB B41 module which are designed specifically for this use and are specified below.
AU540 eNB B41 User Guide About This Document Purpose This User Guide is intended as an instruction manual for professional system integrators to provide step-by-step factory integration instructions for setting up and initial configuration of the AU540 eNB B41 module. Intended Audience This guide is intended for persons who are responsible for installing and performing initial configuration of the AU540 eNB B41 module. These persons should have a working knowledge of the equipment.
AU540 eNB B41 User Guide Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e-mails to Customer Care Help Desk. Once you submit your issue, the system generates a new issue and sends an issue number for your reference.
AU540 eNB B41 User Guide 1 Overview The Airspan AU540 eNB B41 module is a product specific module designed to be embedded in Airspan products. The Wireless protocols that come with this product ensure data security and isolation from interference generated by other radio frequencies. The AU540 eNB B41 module supports MIMO antenna technology and high power output. 1.1 Management Software is upgraded locally and remotely. Designed for local and remote management via TBD 1.
AU540 eNB B41 User Guide 2 Physical Description This section provides a description of the components of the AU540 eNB B41: Dimensions Connector 2.1 AU540 eNB B41 The AU540 eNB B41.
AU540 eNB B41 User Guide 2.1.1 Physical Dimensions The table below lists the physical dimensions of the AU540 eNB B41. Table 6: AU540 eNB B41 Physical Dimentions Parameter Value WxL 149.9 mm (5.0 in) x 159.7 mm (6.29 in) Weight 157 g (5.54 oz) 2.1.
AU540 eNB B41 User Guide 3 Configuration 3.1 Node Management This section pertains to Provider configuration which is performed during initial installation and setup of the unit. Note: Access to the AU540 eNB module is by Telnet or SSH or secure WEB only Note: Only the Service Provider can control the module SW and host SW.
AU540 eNB B41 User Guide Figure 6: Node Management – Cell Properties Figure 7: Node Management - Enable LED UGD-D01112 Airspan Commercial and Internal Use 17
AU540 eNB B41 User Guide Figure 8: Network Profile - Edit Figure 9: Network Profile – VoLTE Configuration UGD-D01112 Airspan Commercial and Internal Use 18
AU540 eNB B41 User Guide Note: The Frequency range and the Maximum Total Tx Power is limited by the AU540 eNB’s software is in full compliance with to the FCC’s requirements.