AirStream 4000/4001 WiMAX CPE User Manual v1.0 AIRSPAN NETWORKS LTD. CONFIDENTIAL This document and the information contained in it is confidential information of Airspan Networks Ltd (Airspan), and shall not be used, or publish, or disclosed, or disseminated outside of Airspan in whole or in part without Airspan’s consent. This document contains trade secrets of Airspan. Reverse engineering of any or all of the information in document is prohibited.
AirStream 4000/4001 WiMAX CPE User Manual Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
AirStream 4000/4001 WiMAX CPE User Manual Table of Contents 1 INTRODUCTION ..................................................................................................................................... 1 2 PRODUCT SPECIFICATIONS ............................................................................................................... 2 2.1 2.2 2.3 2.4 2.5 2.6 3 PRODUCT MODEL OVERVIEW ...........................................................................................................
AirStream 4000/4001 WiMAX CPE User Manual 9 VOIP CONFIGURATIONS .................................................................................................................... 26 9.1 SIP CONFIGURATION ............................................................................................................................. 26 9.1.1 User Configuration.......................................................................................................................... 26 9.
AirStream 4000/4001 WiMAX CPE User Manual List of Figures Figure 1. WiMAX CPE Application in 802.16e Network .............................................................................1 Figure 2. Logon Web Page.............................................................................................................................8 Figure 3. WiMAX CPE Web Management Interface.....................................................................................9 Figure 4. Transfer of T.
AirStream 4000/4001 WiMAX CPE User Manual 1 Introduction Airspan’s WiMAX CPE products are 802.16e WAVE II compliant terminal devices designed for wireless service operators to offer integrated wireless data and voice services over the 802.16e networks. The CPE products will help service providers to rapidly reach targeted customer and gain market share.
AirStream 4000/4001 WiMAX CPE User Manual 2 Product Specifications 2.1 Product Model Overview Model Appearance Airstream 4000/4001 2.2 Description & User Interface Antennal Gain: 15dbi One 10/100M Ethernet Port (RJ-45) One RJ11 Port (AirStream 4001 only) LED Indicator: PWR, RUN, WiMAX (4), LINE 48V/0.
AirStream 4000/4001 WiMAX CPE User Manual LED DESCRIPTION PHONE Phone Line Status FUNCTION Stable ON indicates the line is not ready for use or faulty. Stable OFF indicates the line is ready for use. Flashing Light indicates a call is in progress on the port.
AirStream 4000/4001 WiMAX CPE User Manual DHCP or static IP address assignment Support IP_CS and ETH_CS One MAC address assigned by the vendor LAN Port Networking Built-in DHCP server for LAN devices (The default IP address for the LAN interface is 192.168.0.1) LAN User Access Control IEEE802.3 10Base Ethernet Ethernet Interface IEEE802.3u 100Base Ethernet (Fast Ethernet) IEEE802.
AirStream 4000/4001 WiMAX CPE User Manual WEB based management interface Remote management via Telnet For network management interface, the following are supported: SNMP, TFTP and SYSLOG reporting for Alarms Standard TR-069 management client OMA-DM management client in future release For individual CPE firmware and configuration data file management, the user can use the following methods: Firmware and configuration file upgrade or backup via HTTP WEB interface Firmware upgrade v
AirStream 4000/4001 WiMAX CPE User Manual 3 Getting Started 3.1 Packing list Upon receiving the product, please unpack the product package carefully. Each product is shipped with the following items: CPE Products Quantity 1 Main Unit (ODU) 1 PoE adapter(IDU) 48V/0.4A DC Power Adapter 1 PC Ethernet Cable 1 User CD (optional) 1 Product Warranty Card 1 If you find any of the items is missing, please contact our local distributor immediately. 3.
AirStream 4000/4001 WiMAX CPE User Manual User name and password are required for access to management functions. There are two levels or privileges: administrators’ privilege and normal users’ privileges. Administrator’s privilege is designed for service providers to provision a CPE device before selling or leasing out to end users. By supplying administrator’s user name and password, a technician has access to all configurations of a CPE device.
AirStream 4000/4001 WiMAX CPE User Manual password. If the device WiMAX WAN IP assigned is within the same subnet as the LAN IP, the LAN IP by default will be automatically switched to 10.10.0.1. Input user name and password, and then click on the “OK” button. After a successful log on, the welcome page of web management interface will appear. Figure 2. Logon Web Page 4.2.
AirStream 4000/4001 WiMAX CPE User Manual Figure 3. WiMAX CPE Web Management Interface The left frame in the above web page shows the Configuration Tree, which provides links to detailed configuration pages.
AirStream 4000/4001 WiMAX CPE User Manual The lower right frame of the web page has three buttons: Effective configuration data are stored in RAM (Random Access Memory). Once the CPE is powered off, all effective configurations in RAM will be lost unless they are saved into non-volatile flash memory. Information Users are advised to save configuration changes, after Applying changes in the Detailed Configuration Window.
AirStream 4000/4001 WiMAX CPE User Manual 5 System Information System Information provides both system running status, data (TCP/UDP, RTP) and voice traffic statistics info. It helps user to get a overall view of the device operation status. 5.1 System Status In System Status, plenty of info of the CPE is given, such as Running Info, Version Info, WiMAX Info, Voice Line Info, LAN info, PPP Info. ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual 5.2 Statistics Info Click the “Statistic Info” page, you can review the data and call statistics information of the device. 5.2.1 Data Statistics TCP/UDP Statistics supply both TCP & UDP traffic information in terms of packet numbers and traffic volume in bytes. 5.2.2 Call Statistics Call statistics provides various call statistic figures for both incoming and outgoing calls as shown in the above table.
AirStream 4000/4001 WiMAX CPE User Manual 6 WiMAX Configuration The WiMAX Configuration allows user to view and configure the WiMAX interface. It provides five basic functions: interface information display, radio control management, operator profile, authentication and advanced setting. 6.1 WiMAX Interface Info When clicking on the “Interface Info” link, the following WiMAX interface information is displayed. The networking status is a summary of current wireless link connection.
AirStream 4000/4001 WiMAX CPE User Manual 6.2 Radio Control The Radio Control management allows user to temporally disable the WiMAX connection. But by default, the WiMAX radio will always be on when the CPE just powered up or undergo a restart. The nearby BS list shows the list of Base Stations that the CPE device can connect to. The user can select and switch to connect a different base station. 6.
AirStream 4000/4001 WiMAX CPE User Manual To enable access and roaming services, use the following to configure: Prefered network access provider or Contacted Access Provider List Predered network serviec prpvider or Roaming Access Provider List ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual 6.4 Authentication Setting The CPE supports both TTL and TTLS authentication for user access. The authentication can also be disabled for the CPE device. Both root and user certificate are supported and can be over-written via WEB interface. The CPE may be shipped with the service provider default authentication information. Once connected to the network, the CPE can then be managed by the network management system to update the device authentication information.
AirStream 4000/4001 WiMAX CPE User Manual For TTLS authentication, both MD5 and CHAPv2 are supported. For a successful configuration of the TTLS authentication, the following must be provisioned: 6.5 Root certificate Identify or Network Address Identified (NAI) Inner Identity or User Name Password Advanced Setting Use the advanced setting to select IOT Mode and configure MS Capability and Network Access options.
AirStream 4000/4001 WiMAX CPE User Manual ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual 7 Network Configurations This section discusses the configuration to establish connectivity between a CPE and wireless network. When clicking on the Network Configuration link, the following menu will be displayed. 7.1 WAN Networking Click on “WAN Networking” in the Configuration tree. The web page in the detailed configuration frame will show WAN IP Address Setting and DNS Configuration. For WiMAX access, dynamic IP should be enabled for WAN interface. 7.1.
AirStream 4000/4001 WiMAX CPE User Manual 7.2 LAN Networking An operation mode of Router or Bridge can be selected via Web management. When choosing Router mode, you can also enable or disable DHCP Server, and configure LAN and DHCP Server IP. By default this DHCP server feature is enabled for LAN segment. A default IP address pool is allocated by the CPE. It is not recommended to change this setting in general.
AirStream 4000/4001 WiMAX CPE User Manual 7.4 VPN Networking To enable VPN networking for enterprise user, the CPE has integrated L2TP client function within the device. To use the L2TP function, the user needs to enable and configure the L2TP client as the following. Once the L2TP connection is established, all data from the LAN port will be forwarded to the L2TP server for processing. ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual 7.5 Access Control User can enable and setup MAC Filer to prevent computers with specified MAC address from accessing to CPE. The operator can also configure the User Access Control to limit the device usage by the user. The Max User Allowed, Highest Port Number Allowed and Minimum Inactive Timeout can be configured to restrict the LAN device access. ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual 8 Firewall Configuration Click “Firewall configuration” on the left configuration tree. And then you have the access to Virtual Server and IP Filtering Rules. 8.1 Virtual Server Virtual Server function allows user to expose internal server to the Internet. The following configuration can be used to expose certain server IP and port number to Internet and support DMZ functions.
AirStream 4000/4001 WiMAX CPE User Manual minimize its usage whenever possible. ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual 9 VoIP Configurations 9.1 SIP Configuration SIP related configurations concern CPE as a SIP client, Registrar and Proxy Servers. Click on “SIP Configuration” in the Configuration Tree to access the related web management page. 9.1.1 User Configuration Internally FXS ports are counted from 0. Phone line 1 maps to FXS Port No 0. “User ID” maps to dial number. Apply settings if changes are made in the above section. Next comes to Registrar configurations.
AirStream 4000/4001 WiMAX CPE User Manual Proxy can be enabled and configured. And if more than one Proxy Addresses are supplied, the CPE will try each Proxy sequentially if a request to a Proxy times out with no responses. Apply settings if changes are made in the above section. After completing all settings, you may uncheck “Enable Register” and apply settings to de-register the FXS port. Check “Enable Register” and apply settings again to perform another registration.
AirStream 4000/4001 WiMAX CPE User Manual Mapping of Configuration to SIP Messages REGISTER and INVITE Message Usage in SIP Messages Other SIP Messages User ID the "username" part of SIP URI in From, To, Contact attributes, e.g. "85412006" in 85412006@myisp.net. (The "host" part of SIP URI is taken from "Local Hostname" field.
AirStream 4000/4001 WiMAX CPE User Manual “Number Prefix”, “Min Length of Number”, and “Max Length of Number” are used in combination to define a condition. “Route Address” may specify another SIP capable node to route a call. If this field is left empty, configuration in User Agents setup applies. This feature was widely used for point to point calls without involvement of Proxy servers, in early years of VoIP network evolution.
AirStream 4000/4001 WiMAX CPE User Manual So a dial number 0212401 is modified to 021 8541 2401 before the CPE device sends out a call invite. 9.3 Call Configuration Call Configuration section defined a few behavior when a call is outgoing or incoming. Click on “Call Configuration” in the Configuration Tree. The following sections will be displayed in the detailed configuration window: 9.3.1 Dial Plan Configuration The CPE collects dial numbers from external phone or fax.
AirStream 4000/4001 WiMAX CPE User Manual A few options are available in the drop down list of Port Select Mode in Group: Early Release First: the line which was released earliest receives an incoming call. Random: an incoming call is randomly dispatched to one of the lines. Order: an incoming call is dispatched to lines sequentially. 9.3.
AirStream 4000/4001 WiMAX CPE User Manual good quality. However, in networks with poor quality, packet losses or disordered delivery of RTP packet may cause error. An alphanumerical digit input by the caller may be interpreted wrongly as another digit. o o RFC2833: As a second option, the CPE can recognize the tones and translate them into a name, such as numeric input, or Flash. RFC2833 defined payload format for named telephone events, such as numeric input, or Flash.
AirStream 4000/4001 WiMAX CPE User Manual Information G.723 and G.729 cannot be enabled at same time. PCMu or PCMa Law can be chosen in Line Configurations. Only one codec can be used at a time. Most legacy fax devices adopt ITU-T Group 3 fax protocol published in 1990. The protocol is composed of server standards that specify different parts the fax call. Amongst them T.
AirStream 4000/4001 WiMAX CPE User Manual The configurations are explained in more details: Fax Mode: Transparent or T.38. The later is more preferred. Rate Management: Local TCF, and Transferred TCF. supported. UDP Error Correction: Redundancy or FEC. At this moment, only Redundancy is supported. Redundancy method means payload transmitted in previous IP packet is repeated in a later packet.
AirStream 4000/4001 WiMAX CPE User Manual specified by user by dialing the service codes, e.g. *90075533639088 specifies that incoming calls should be forwarded to 075533639088. 9.5.1 Service Codes Configuration Many of the enhanced services need to be provisioned with the proper activation codes to work with the soft switch. The default service codes are displayed below. Service codes are configurable.
AirStream 4000/4001 WiMAX CPE User Manual Call waiting: For the second incoming call, the user has the following two options to take the new incoming call: ■ Option 1 - flash hook and press 1, the old call will be dropped and the new call will be connected. ■ Option 2 - flash hook and press 2, the old call will be hold and the new call will be connected. Flash hook and press 2 again will switch the connection to the previous call.
AirStream 4000/4001 WiMAX CPE User Manual nothing. Hotline is configured on per FXS port basis. For each port, you are allowed to set the Whitelist and Blacklist. Blacklist gives the numbers which you are not allowed to call, and Whitelist gives you the only numbers you are allowed to call. Type in the number in the blank area directly, and a symbol “|” is used between two numbers. 9.7 Port Configuration Port configuration defines physical and electrical layer parameters, such as port transmit power.
AirStream 4000/4001 WiMAX CPE User Manual On Port Gain settings, the value before “/” is for transmission, the one after “/” is for receiving. The min and max hook times are relevant to the detection of a flash. If the phone is put on and off hook quickly and the duration is between min and max hook time, the operation is considered the same as pressing the Flash button. 9.7.2 Port Application Attribute The CPE allows controlling fax function by each port. Configuration page is as follows: 9.7.
AirStream 4000/4001 WiMAX CPE User Manual 9.8 STUN Configuration STUN (Simple Traversal of User Datagram Protocol (UDP) Through Network Address Translators (NATs)) is a network protocol allowing clients behind NAT (or multiple NATs) to find out its public address, the type of NAT it is behind and the internet side port associated by the NAT with a particular local port. This information is used to set up UDP communication between two hosts that are both behind NAT routers.
AirStream 4000/4001 WiMAX CPE User Manual 10 Device Management When clicking on the Device Management link, you will be prompted with the follow navigation menu: 10.1 Device Identity Use the following configuration page to add Device Name, Host Name, Domain Name and Contact Info for the CPE device. 10.2 TR069 Configuration To manage the CPE via TR069, you need to configure the TR-069 client. You can set the ASC URL manually by directly typing.
AirStream 4000/4001 WiMAX CPE User Manual You can also obtain the ACS URL automatically by enabling WIB. Set the WIB Operator Domain, WIB Server URL and EMSK Value (or enable the default EMSK) correctly to get the ACS URL, ACS Username and Password, and to renew the local Certificate. Choose the right path and load the right ASS Certificate. The ASC Certificate Info will be shown. ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual Enable the STUN to start the STUN function. You can set the server address, server port, username, password, minimum and maximum keep alive period. 10.3 Remote Reporting Via the Web Management, the contents of log and alarm can be uploaded to specified server. Syslog and TFTP reporting are supported. ©1998-2010 Airspan Networks Ltd.
AirStream 4000/4001 WiMAX CPE User Manual 10.4 Management Options Management Options setting allows you enable or disable device management options according to your needs. Remote device management via WiMAX WAN or local management via LAN device can be controlled. Microsoft UPnP service is also configurable to allow Microsoft Windows user to browse the device directly from the desktop.
AirStream 4000/4001 WiMAX CPE User Manual 11 System Maintenance Click on “System Maintenance” in the Configuration Tree in the left frame of browser window and then a subtree with several items will be shown. 11.1 Operation Information By clicking “Operation Info” in the subtree, the following system information will be displayed in the detailed configuration frame: Basic system information of the device is shown, such as service state, IP address, MAC, System Version. The information cannot be modified.
AirStream 4000/4001 WiMAX CPE User Manual 11.2 Load and Backup This section demonstrates “Load” and “Backup” transaction via a web management interface. Let us start with discussion of a few terminologies: Program refers to the file which contains binary instruction sets that controls the CPE system. Data refers to the file which contains network and user specific configuration Load refers to transferring of system program file or configuration data file from an external host into a CPE.
AirStream 4000/4001 WiMAX CPE User Manual 4. 5. 6. Select the file “iad.prg”, click the “Open” button. Click the [Load] button. Reset system after loading finished. 11.2.1.2 Save system configurations from CPE The steps of backup configuration files via HTTP are as follows: 1. 2. 3. 4. Choose the type of backup file as "Data" in the “File Type" column. Click the “backup" button. Click the “Save” button. Select the file name and click the “Save” button.
AirStream 4000/4001 WiMAX CPE User Manual The steps of Load system software or configuration via TFTP are as follows: 1. 2. 3. 4. 5. Obtain the correct release of program file; the program file in this example is named “iad.prg”. Obtain the IP address of the TFTP server. The IP address of the external host is 192.168.0.18 Type IP address of the TFTP server in the “TFTP server address" field. Choose the type of the loaded files as "Program" in the “File Type" field.
AirStream 4000/4001 WiMAX CPE User Manual Parameters that are prone to cause operational failure are forbidden from access, e.g. change of dial number. Both admin and user has preferred language, and password setting. User name is the identifier of user, use admin or user to log on. Level is the privilege level of a certain user. Language defines default display language of web management pages for a user. Click on the “User Account” in Configuration Tree.
AirStream 4000/4001 WiMAX CPE User Manual To set system time, type in all the fields and click the [Apply] button. 11.4.2 NTP Server Configuration The CPE also supports the NTP (Network Timing Protocol) to synchronize its system time with a clock source with higher accuracy. 11.5 Alarms Information The CPE capture system faults and report them in the Alarms Information web management page. The Alarm information provides traces of fault and helps troubleshooting the device. 11.5.
AirStream 4000/4001 WiMAX CPE User Manual 11.5.
AirStream 4000/4001 WiMAX CPE User Manual ©1998-2010 Airspan Networks Ltd.