User's Manual
Table Of Contents
- Purpose
- Targeted Audience
- Referenced Documentation
- Conventions
- Human Exposure to Radio Frequencies
- Radio Interference
- Avoiding Radio Interference
- Modifications
- General
- Manufacturer's Disclaimer Statement
- European Community, Switzerland, Norway, Iceland, and Liecht
- Declaration of Conformity with Regard to the R&TTE Directive
- ProST Frequency Ranges
- Main Features
- Architecture
- ProST Protocol Stack
- Theory of Operation
- Package Contents
- Minimum PC Requirements
- Required Tools
- Radio Site Planning
- ProST Physical Description
- SDA-1 Physical Description
- SDA-4S Type II and SDA-4S/VL Type II (Optional)
- Mounting the ProST
- Wall Mounting
- Pole Mounting
- SDA-4S
- Connecting to IDU
- Connecting to LAN Network
- Connecting AC/DC Power Adapter
- Mounting AC/DC Power Adapter
- DC Power Source
- AC Power Source
- Connecting Lightning and Surge Protector
- Antenna Alignment using RSSI LED Plug Adapter
- LED Status
- 1. Disclaimer
- 1.1 Safety Warnings
- 1.2 Important Warning Symbols
- 1.3 Important Service Information
- 1.4 UL Information
- 1.5 CE Notice
- 1.6 European Community, Switzerland, Norway, Iceland, and L
- 1.7 CAUTION
- 1.8 Lightning Protection
605-0000-706 ProST Installation User Guide-Rev E
46
In addition, Airspan offers an optional third-party outdoor, lightning and surge protector that
protects the ODU-to-IDU CAT 5 cable's power and data signals from any electrical surges due to
lighting strikes.
Note: ProST is designed with a built-in lightning surge protection that complies with the
Surge Immunity standard EN 61000-4-5.
DC Power Source
ProST can be connected directly to a DC power supply unit that supplies 10 – 52 VDC (0.2 to 0.9 A;
15W maximum, assuming up to 100-m cable length between ProST and power source).
The ProST-to-DC power connectivity is supported by a splitter cable. One end of the splitter cable
connects to the ProST (using the RJ45-to-DB15 adapter or connecting directly to the 15-pin D-type
port); the other end of the cable splits into the following two wire groups:
One group for the subscriber's Ethernet interface (four wires for the Tx and Rx signals)
One group for the DC power source interface (two wires for +48 VDC and +48 RTN)
Warning: ProST should be powered by a safety approved Class II limited DC power
source with maximum current of 1A.
The figure below displays the ProST-to-DC power supply cable setup: