User's Manual

Table Of Contents
605-0000-707 ProST 49 Installation User Guide-Rev C
44
ProST)
AC power socket
Safety UL/CUL UL60950, TUV EN60950, CB
BN55022
Standards
compliance
EMI/RFI VDE and FCC limit B
Operating
temperature
0 to +40°C
Storage
temperature
-20 to +85°C
Environmental
Humidity 5 to 96% RH non-condensing
Requirements 110/240 VAC, 50/60 Hz (standard
electrical wall outlet)
Output -48 VDC nominal
Power
Mechanical AC power cord plugged into AC socket
Dimensions 200 x 150 x 40 mm (7.87 x 5.9 x 1.57
inches)
Physical
dimensions
Weight 0.577 kg
Lightning/Surge Protector Specifications
The PolyPhaser lightning and surge protector specifications are listed in the table below:
Parameter Value
Connections: # 16 - 28 AWG
Temperature: -40° to +65° C storage; -40° to +50° C operating
Vibration: 1 G @ 5 Hz to 100 Hz
BELLCORE #TA-NWT-000487
Procedure 4.11
Wind Driven (70 MPH) Rain
Environmental:
Intrusion Test
Surge: BELLCORE 1089, 10/1000 uSec @ 100 A
Agency Approval: UL497B - Listed
Application Turn On Series
Resistance
Capacitance Current IX-H
(up to
100Mbps)
CAT5
Compatible,
UTP, STP
+ 8 Vdc,
Common
and
Differential
Mode
1 Ohm
Typical
Common Mode:
15 pF
Typical;Differential
Mode: 30 pF
Typical
--
Modules:
IX-M (up to
25Mbps) RS
232
+/- 30 Vdc 1 Ohm
Typical
Differential Mode:
100 pF Typical;
Differential Mode:
100 pF Typical;
--