User Manual
Table Of Contents
- 1.1 0BPurpose
- 1.4 1BReferenced Documentation
- 2.1 2BProST Frequency Ranges
- 2.2 3BProST-2 Frequency Ranges
- 2.3 4BArchitecture
- 2.4 5BModels
- 3.1 6BPackage Contents
- 3.2 7BMinimum PC Requirements
- 3.3 8BRequired Tools
- 3.4 9BRadio Site Planning
- 4.1 10BProST Physical Description
- 4.2 11BSDA-1 Physical Description
- 4.3 12BSDA-4S Type II and SDA-4S/VL Type II (Optional)
- 4.4 13BSDA-4SDC Type II (Optional DC power supply)
- 5.1 14BWall Mounting
- 5.2 15BPole-Mounting
- 5.3 16BMounting the SDA-4S
- 6.1 17BConnecting to IDU
- 6.2 18BConnecting to LAN Network
- 7.1 19BDC Power Source
- 7.2 20BConnecting the SDA-4SDC Type II (Optional DC adapter)
- 7.3 21BAC Power Source
- 8.1 22BHousing the Connectors
- 8.2 23BConnecting to the SDA-4SDC
- 9.1 24BPolyPhaser Wiring Diagram
- 9.2 25BLightning and Surge Protection Connection Scenarios
- 10.1 26BLED Status
- 12.1 27BTroubleshooting
- 12.2 28BGlossary of Terms
- 12.3 29BRevision History
- 12.4 30BContact Information
ProST Hardware Installation User Guide
Page 45 Commercial in Confidence UWB-D00111 Rev K
Note: A DB15-to-RJ45 (gray colored) adapter for plugging into the ProST's
15-pin D-type port (pins 7 & 8 disconnected) is included, replacing previous
(black colored) adapter.
Note: Only pins 1 to 6 are used.
• When using previous black adapter (outdoor DB15-to-RJ45), pins 7 and 8
must not be wired to either end.
• The wire color-coding described in the table is Airspan's standard for wire
color-coding. However, if you implement your company's wire color-coding
scheme, ensure that the wires are paired and twisted according to pin
functions listed in the table above (e.g. Rx+ with Rx-).
• The maximum CAT 5Ee cable length for ODU/IDU connectivity is 100
meters.
To connect the ProST to the SDA-1:
1. Attach the DB15 side of the DB15-to-RJ45 adapter to the ProST's 15-pin D-type port
(female), labeled DATA & PWR.
2. Plug the RJ-45 connector of the Category 5 Ethernet cable (not supplied) into the RJ-45 port
of the DB15-to-RJ45 adapter.
3. Plug the RJ-45 connector, at the other end of the Category 5 Ethernet cable, into the SDA-
1's RJ-45 port labeled RADIO.
Figure 33 - ProST & SDA-1