Tip: It is good practice to label both ends of the cable to identify which AirSpeed 1050 unit it is
connected to.
Tip: It is good practice to leave a spare loop of cable (approximately 0.5m). This will allow for
easier wiring and will allow the cable to be re-terminated if necessary in the future.
Note: When securing the cable make sure there is no tension on the cable so that it is easy to
disconnect and re-connect for future maintenance actions.
5.2.1 AC Cable Preparation
Caution: Safety - Disconnection of power supply
When AirSpeed unit is connected directly to wiring a suitably rated and easily accessible
circuit breaker shall be incorporated externally to the equipment.
Power source disconnection is required before disconnecting the power connector.
Warning: This unit incorporates double pole/neutral fusing. Both the Line & Neutral have fuses
in them.
Warning: The onsite source circuit breaker (6A) should be gang operated, two (2) pole (single
phase type).
Note: Required AC power cable – 3 wire - 18 AWG within a pipe enclosure, connected directly to
the building electrical power supply.
The following displays the proper steps for AC cable preparation:
1. Strip back and remove the outer sheath to expose the inner insulated wires to a length of
34mm max (1.34 in). Then strip back 8mm± 2 (0.31 in) of the inner core insulation.
Figure 12: Stripping Dimensions (AC Cable)
2. Open the housing lock by sliding up then lift the clamp handle.
Figure 13: Open Housing Lock