AirSpeed 1050 Installation Guide Part Number: DUG01545 System Release: 16.
© Copyright by Airspan Networks Inc., 2019 - 2019. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary, privileged and intended only for the recipient. As such, the information is subject to all relevant copyright, patent and other laws protecting intellectual property, as well as any spec ific agreements protecting Airspan Networks Ltd. rights in the aforesaid information.
Table of Contents Document Information ............................................................................... 1 Document Approvals .............................................................................................. 1 Revision History ..................................................................................................... 1 Warnings and Cautions ............................................................................. 2 Human Exposure to Radio Frequencies ...............
AirSpeed 1050 Installation Guide Intended Audience ............................................................................................... 11 Related Reading .................................................................................................. 11 Customer Care Help Desk ......................................................................12 Airspan Encourages Comments .......................................................................... 12 1 Introduction .......................
AirSpeed 1050 Installation Guide Figures Figure 1: AirSpeed 1050 .................................................................................................................. 10 Figure 2: AirSpeed 1050 .................................................................................................................. 14 Figure 3: AirSpeed 1050 Overall Dimensions ................................................................................... 17 Figure 4: AirSpeed 1050 Bottom .........................
AirSpeed 1050 Installation Guide Figure 37: Place Tightening Cone on Split Gland ............................................................................. 33 Figure 38: Tighten gland Nut............................................................................................................ 33 Figure 39: Close the Lever............................................................................................................... 33 Figure 40: Secure Housing Lock ......................................
AirSpeed 1050 Installation Guide Table 6. AirSpeed 1050 Physical Dimensions .................................................................................. 17 Table 7. AirSpeed 1050 Environment Compliance ........................................................................... 18 Table 8: Outdoor Power Cable Requirements .................................................................................. 25 Table 9: Recommended Gland Size..................................................................
AirSpeed 1050 Installation guide Document Information This document details procedures for installing the Airspan’s AirSpeed 1050 Pico-class LTE eNodeB variant. Document Approvals Department Name Role Approval date Product Management STS Product Line Manager R&D EPI Digital HW Group Manager Revision History Document owner: Shlomi Tsur, PLM Revision Date Summary of Changes Created by 0.1 - 0.3 January 2019 Initial document & comments MSF 0.
AirSpeed 1050 Installation Guide Warnings and Cautions Human Exposure to Radio Frequencies The AirSpeed 1050 when operational should be operated from a minimum safe distance of 2ft (64cm). Avertissement et Precautions d’Utilisation Exposition des personnes aux fréquences radioélectriques Les antennes d’AirSpeed 1050 quand opérationnel doivent être installée et utilisée de façon à garantir la distance minimale de sécurité de 2ft. (60cm).
AirSpeed 1050 Installation Guide Général Seul le personnel qualifié peut être autorisé pour installer ou remplacer l’équipement ainsi qu’effectuer les opérations de maintenance pour cet équipement. L’équipement ne peut pas être vendu en grande distribution ou par commande via email à destination du public. Il doit être vendu aux opérateurs de télécommunications. Son installation doit être contrôlée Son Installation doit être effectuée par des professionnels autorises.
AirSpeed 1050 Installation Guide 12. The circuit breaker should be easily accessible in case you have to disconnect the device. 13. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. Securite 1.
AirSpeed 1050 Installation Guide Attention aux Voltages Hasardeux Sur les installations de réseau électrique de type courant alternatif (CA) , des voltages hasardeux peuvent survenir. Garder une Attention particulière lors d’une vérification ou de travaux sur réseau électrique CA. Retirer tous bijoux en métal qui pourraient entrer en contact avec l’alimentation ou le réseau CA.
AirSpeed 1050 Installation Guide a. The terminal does not function after following the operating instructions outlined in this manual. b. The product has been dropped or the housing is damaged. Locate the serial number of the terminal and record this on your registration card for future reference. Also record the MAC address, located on the product sticker. UL Information - The equipment must be properly grounded according with NEC and other local safety code requirements.
AirSpeed 1050 Installation Guide Outdoor Cabling - Connected cables should be outdoor grade with UV protection. - Use shielded out CAT6 cabled terminated with metallic RJ45 connectors. - Surge protection circuit must use a minimum 14AWG grounding cable.
AirSpeed 1050 Installation Guide Român: Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei 1999/5/CE. The Declaration of Conformity related to this product can be obtained from PLM@Airspan.com. GPS Compliance The GPS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
AirSpeed 1050 Installation Guide Maximum Output TX Total Power Table 1: AirSpeed 1050 FCC Maximum Output TX Total Power Frequency Band (MHz) TX (dBm) 2496 - 2690 FCC EIRP (dBm) 35 47 Antenna Gain (dBi) Variant 12 1050 Caution: Do not set maximum output TX power to higher than local regulations. Power Consumption AirSpeed 1050 has a Max nominal power consumption of 45W.
AirSpeed 1050 Installation Guide Antenna System The AirSpeed 1050 includes embedded antennas: 2x SBA. Each SBA includes two antenna elements which can be switch on/off.
AirSpeed 1050 Installation Guide About This Document Purpose This guide provides the workflow and step-by-step procedures for Installing the AirSpeed 1050. These procedures include: Verify prerequisites Install the AirSpeed 1050 Connect and manage cables Intended Audience This guide is intended for persons who are responsible for installing the AirSpeed 1050 equipment. These persons should have a working knowledge of the equipment.
AirSpeed 1050 Installation Guide Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e-mails to Customer Care Help Desk. Once you submit your issue, the system generates a new issue and sends an issue number for your reference.
AirSpeed 1050 Installation Guide 1 Introduction This section provides a descriptive overview of the Airspan’s AirSpeed 1050 variant(s) and its place in the Airspan product suite. AirSpeed 1050 is a standalone product with fiber and copper backhaul. It includes dual sector access with SBA antenna. The product is aimed for outdoor deployment, on a pole top or side as well as wall mounting. 1.
AirSpeed 1050 Installation Guide Figure 2: AirSpeed 1050 Note: The illustration above displays the AirSpeed 1050 unit.
AirSpeed 1050 Installation Guide 2 Verifying Prerequisites Prior to installing the AirSpeed 1050, verify the required safety, power, tools, parts and components. This chapter includes the hardware, software, and client requirements for installation. Verify the availability of: AirSpeed 1050 unit Mounting Kit Desired location with available power source 2.1 Verify the Tools Table 4.
AirSpeed 1050 Installation Guide Installation Kit / Part Product Code AS P/N Description OR Mounting KIT Short Band 903-03-360 Pole Mounting Clamp Bracket (x1) Sems Hex-Head Bolt M8x20 ISO4017 with 2 Washers-all A2 (x2) Maxi Clamp, band 14mm (9/16in) wide + quick adjust lock, 51-178mm (2-7in) pole diameter.
AirSpeed 1050 Installation Guide 3 Physical Description AirSpeed 1050 is in an all outdoor enclosure. This section provides the physical attributes of the AirSpeed 1050. Figure 3: AirSpeed 1050 Overall Dimensions 3.1 AirSpeed 1050 Physical Dimensions Table 6. AirSpeed 1050 Physical Dimensions Dimensions Volume Dimensions (H x D) Comment 195 x 430 mm (7.68 x 16.93in.) – including bracket 195 x 300 mm (7.68 x 11.1in.) – without bracket The physical dimensions exclude connectors 9.
AirSpeed 1050 Installation Guide 3.2 Bottom View The following figure shows the AirSpeed 1050 from the bottom. Figure 4: AirSpeed 1050 Bottom 3.3 Power AirSpeed 1050 supports direct connection to DC or AC power source variants. Operational Voltage Range: DC - 40.5 to–57.0 VDC AC - 100~240 VAC, 50-60Hz, 2.5A 3.3.1 Environmental Note: AirSpeed 1050 is not meant to be used in a Marine environment.
AirSpeed 1050 Installation Guide Type Rain and dust ingress protection DUG01545 Details IP66 Airspan Commercial and Internal Use 19
AirSpeed 1050 Installation Guide 4 Installation of AirSpeed 1050 4.1 Mounting AirSpeed 1050 is installed on a pole (side or top) or wall and comes fully assembled. Prior to installation of the AirSpeed unit the mounting bracket must first be affixed in place on the Pole or Wall. Caution: Proper local rigging and hoisting practices should be followed when installing the AirSpeed 1050.
AirSpeed 1050 Installation Guide 4.1.1 Pole Mount Assembly The following images show the pole mount assembly on a pole. 1. Select the location on the pole to mount the AirSpeed 1050 mounting clamp bracket. You can attach the AirSpeed 1050 to any pole from 63-406mm (1/2-16in) or 51-178mm (2-7in) pole diameter, (dependent on the mounting kit). 2. Position the mounting clamp bracket as shown below. 3.
AirSpeed 1050 Installation Guide 4.1.2 Wall Mount Assembly The following images show the bracket wall mount assembly. 1. Select the location on the wall to mount the AirSpeed 1050 mounting bracket. 2. Position the mounting clamp bracket as shown below. Be sure to position the mounting bracket straight with level mounting to ensure the unit sits uniformly. 3. Mark the wall through the holes on the mounting bracket at the required height. 4.
AirSpeed 1050 Installation Guide 4.1.3 Securing the Unit to the Mounting Clamp Bracket To mount the AirSpeed unit onto the Mounting Clamp Bracket, perform the following: 1. Lift the unit and slide the Mounting Bracket onto the Mounting Clamp Bracket. 2. Slide the unit downward until the two (2) holes in the Mounting Bracket line up with the two (2) M8 threaded holes in the Mounting Clamp Bracket. Figure 7: Assembly on Pole 3.
AirSpeed 1050 Installation Guide AirSpeed 1050 can also be mounted on top of pole, as shown below (for example). Note: Extension pole and any required hardware for mounting on top of a pole are not included in should be obtained by the installer. Figure 9: AirSpeed 1050 on Top Pole - Example (Shown Wired) AirSpeed 1050 mounted on a wall.
AirSpeed 1050 Installation Guide 5 Connect and Manage Cables 5.1 Connecting the Ground Cable Connect the ground lug with the ground cable (not supplied) to the M6 threaded bolt on the bracket assembled on the unit clearly marked with the universal ground symbol. Note: Cutting the ground cable to the required length and crimping the grounding lug is performed by the Installer. The cable should be grounded according to international or local standards. Figure 11: Ground Connection 5.
AirSpeed 1050 Installation Guide Tip: It is good practice to label both ends of the cable to identify which AirSpeed 1050 unit it is connected to. Tip: It is good practice to leave a spare loop of cable (approximately 0.5m). This will allow for easier wiring and will allow the cable to be re-terminated if necessary in the future. Note: When securing the cable make sure there is no tension on the cable so that it is easy to disconnect and re-connect for future maintenance actions. 5.2.
AirSpeed 1050 Installation Guide 3. Separate the housing into its component sections. Figure 14: Seperate into Sections 4. Insert the Gland nut through the other end of the cable. Figure 15: Insert Gland Nut 5. Feed the end of the source power cable through the housing of the AC connector. Figure 16: Pass Cable Through 6. Insert the prepared ends of the cable into the inner part of the connector housing. Caution: Verify the wire polarity before securing. Figure 17: Insert Wire to Housing 7.
AirSpeed 1050 Installation Guide Figure 18: AC Wire Placement 8. Tighten the three (3) set screws as shown below. Figure 19: Tighten Three (3) Set Screws 9. Insert into outer housing until “click” in place, align marks for proper alignment. Figure 20: Cable Click in Place 10. Place the split rubber gland onto the cable.
AirSpeed 1050 Installation Guide 11. Verify the gland size as shown below. Table 9: Recommended Gland Size Diameter Recommended Gland Size From 6.6min to 7.95 Max From 7.5min to 8.95 Max “Φ8” “Φ9” From 8.6min to 9.95 Max “Φ10” From 10.3min to 11.03 Max “Φ11.5” Note: The gland size is written on the edge of the gland. Figure 22: Gland Size on Edge Note: The tolerances of the diameter should be taken into account to make sure it is always within the specified range. 12.
AirSpeed 1050 Installation Guide 14. After tightening the gland nut, close the lever. Figure 25: Close the Lever 15. Secure the lock by sliding the secondary lock/button; assembly is now ready Figure 26: Secure Lock Note: When securing the cable verify there is no tension on the connector so that it is easy to disconnect and re-connect for future maintenance actions.
AirSpeed 1050 Installation Guide 2. Open the housing lock by sliding up then lift the clamp handle. Figure 28: Open Housing Lock 3. Separate the housing into its component sections. Figure 29: Seperate into Sections 4. Insert the Gland nut through the other end of the cable. Figure 30: Insert Gland Nut 5. Loosen the strap clamp and feed the prepared end of the source power cable into the inner part of the DC connector housing. Figure 31: Pass DC Cable Thru 6.
AirSpeed 1050 Installation Guide Caution: Verify the wire polarity before securing. Figure 32: Tighten Two (2) Set Screws 7. Tighten the strap clamp screw as shown below. Figure 33: Tighten the Strap Clamp 8. Insert into outer housing until “click” in place, align marks for proper alignment. Figure 34: Align Marks + Click in Place 9. Place the split rubber gland onto the cable.
AirSpeed 1050 Installation Guide Figure 36: Gland Size on Edge Note: The tolerances of the diameter should be taken into account to make sure it is always within the specified range. 10. Place the tightening cone onto the split rubber gland. Figure 37: Place Tightening Cone on Split Gland 11. Tighten the gland nut with a 21mm wrench, to a torque of no more than 2-2.5 Nm (1.47 – 1.84 ft-lb) max. Figure 38: Tighten gland Nut 12. After tightening the gland nut, close the lever.
AirSpeed 1050 Installation Guide 13. Secure the lock by sliding the secondary lock/button; assembly is now ready. Figure 40: Secure Housing Lock Note: When securing the cable verify there is no tension on the connector so that it is easy to disconnect and re-connect for future maintenance actions. 5.2.
AirSpeed 1050 Installation Guide 4. Insert the gland nut through the front end of LC Duplex assembly. Figure 43: Gland Nut on Cable 5. Insert the “split tightening cone” from the side of the cable. Figure 44: Insert Tightening Cone on Cable 6. Insert the “split rubber gland” from side of the cable. For recommended gland size see Table 9: Recommended Gland Size Note: Inner diameter of rubber gland is in the range of 6 to 8mm (0.20-0.31) range. Figure 45: Insert Rubber Gland on Cable 7.
AirSpeed 1050 Installation Guide 8. Insert the LC Duplex cable into the transceiver. A “click” is heard when engaged. Figure 47: Insert Cable into Transceiver 9. Insert the holder subset section from the front end of Transceiver. Figure 48: Insert Holder over theTransceiver 10. Fix the holder into the housing base. A “click” is heard when engaged. Figure 49: Holder into Housing Base 11. Secure the holder into the transceiver, “click” when engaged.
AirSpeed 1050 Installation Guide 12. Lift the lever of housing base slightly so that the rubber gland, tightening cone and gland nut can be inserted and tightened correctly. Figure 51: Lift Lever 13. Push to insert the rubber gland. Figure 52: Insert Gland 14. Push to insert the tightening cone. Figure 53: Insert Cone 15. Tighten the gland nut with a 21mm wrench, to a torque of no more than 2-2.5 Nm (1.47 – 1.84 ft-lb) max.
AirSpeed 1050 Installation Guide 16. Secure the lock by sliding the secondary lock/button, so that lever can’t be lifted; assembly is now ready for insertion. Figure 55: Secure Housing Lock 5.2.4 Copper Ethernet Cable Preparation Note: A pre-assembled RJ45 cable is required for the Copper Ethernet assembly. The following displays the proper steps for the Copper (ETH) cable preparation: 1. Have the pre-assembled RJ45 cable assembly ready. Note: Diameter of cable is in the 6 to 7mm (0.24-0.28) range.
AirSpeed 1050 Installation Guide 4. Insert the “split rubber gland” from side of the cable. Note: Inner diameter of rubber gland is in the range of 7 to 8mm (0.28-0.31) range. Figure 59: Insert Rubber Gland on Cable 5. Insert the housing onto the RJ45 cable. Figure 60: Insert Housing onto Cable 6. Insert the holder section onto the front of the RJ45. Figure 61: Insert Holder onto RJ45 7. Fix the holder into the housing base. A “click” is heard when engaged.
AirSpeed 1050 Installation Guide 8. Ensure correct alignment of the RJ45 in the hosing by raising the lever to allow free movement and then push the RJ45 plug into the plug cap to ensure proper location, then lock the cap. Figure 63: Align RJ45 into Holder 9. Lift the lever of housing base slightly so that the rubber gland, tightening cone and gland nut can be inserted and tightened correctly. Figure 64: Lift Lever 10.
AirSpeed 1050 Installation Guide 12. Close the lever and secure the lock by sliding the secondary lock/button, so that lever can’t be lifted; assembly is now ready for insertion.
AirSpeed 1050 Installation Guide A Job Sheet This job sheet enables the users to keep track of their installation. It covers all the prerequisites required for accomplishing the AirSpeed 1050 installation.
AirSpeed 1050 Installation Guide B Abbreviations Term Definition AC Alternating Current BH Backhaul DC Direct Current eNb eNodeB ETH Ethernet (cable) FDD Frequency Division Duplex FTP File Transfer Protocol LTE Long Term Evolution, marketed as “4G LTE”, is a standard for wireless communication of high-speed data for mobile phones and data terminals NEC National Electric Code UE User Equipment WEEE Waste Electrical and Electronic Equipment DUG01545 Airspan Commercial and Internal Us