Warning: This unit incorporates double pole/neutral fusing. Both the Line & Neutral have fuses
in them.
Warning: The onsite source circuit breaker (6A) should be gang operated, two (2) pole (single
phase type).
The following displays the proper steps for DC cable preparation:
1. Strip back and remove the outer sheath to a length of 9.0mm± 2 (0.35 in) to expose the inner
insulated wires to a length of 13.5mm± 2 (0.53 in). Then strip back 7mm± 2 (0.27 in) of the
inner core insulation.
Figure 40: Stripping Dimensions (DC Cable)
2. Open the housing lock by sliding up then lift the clamp handle.
Figure 41: Open Housing Lock
3. Separate the housing into its component sections.
Figure 42: Seperate into Sections
4. Insert the Gland nut through the other end of the cable.