Product Info

WipLL Radio Technology - Physical Layer System Description
2-24 Airspan Networks Inc. 25030311-08
2.6.2.2. Link Budget
The coverage analysis of WipLL includes the analysis of the power balance between
the transmitter and the receiver, threshold considerations, margins, reserves, and
certain statistics of the system. Therefore, the lead-in reception level is measured by
the following equation:
Rx = Tx – LossTx + AntGainTx – PathLoss + AntGainRx – LossRx
Where,
Rx =
Reception level in dBm
Tx =
Transmitter power in dBm (27 dBm in the WipLL system)
LossTx =
Transmitter losses in dB (0 dB in the WipLL system)
LossRx =
Terminal receiver losses in dB (0 dB in the WipLL system)
AntGainTx =
Transmitter antenna gain
AntGainRx =
Receiver antenna gain in dBi (decibels referenced to isotropic
radiator)
PathLoss =
Propagation loss in dB
Note: Both the base station and the subscriber site can serve as transmitter o
r
receiver. For downlink budget, the transmitter is the base station and the