User's Manual
Hardware Installation Manual Installing and Configuring the IDR
02030311-03 Airspan Networks Ltd. 10-15
! There should not be any visible sign of water or dampness on or around the
power outlet.
! The plug and socket assemblies are to be firmly secured.
! The power outlet shall be checked using a proprietary plug tester such as a
‘Martindale Ze’ type. Checks are required to verify the earth loop impedance
value and the presence of phase, neutral and earth connections.
Connector: 6-Pin power connector
Cable: 3-core 0.7mm² type
Connector pinouts:
Pin Function
1 +6.5V
2 +5V
3 3.3V
4 GND
5 Not connected
6 Not connected
To connect the power:
1. Connect the IDR’s 6-Pin power port to the supplied power adapter.
2. Connect the power chord to the adapter and then connect the other end to the
wall socket.