User's Manual
Hardware Installation Guide Mounting the Devices
02030311-07 Airspan Networks Inc. 13-3
A 1-meter separation is required between SPRs when on the same sector and
transmitting to the same BSR without requiring shielding (see Figure 13-3).
1.0 metre
Figure 13-3: SPR separation when transmitting on the same sector to the same BSR
SPR wall mounting is performed in two stages:
! Attaching the mounting bracket to the SPR’s mounting holes.
! Attaching the mounting bracket (attached to the SPR) to the wall.
To wall mount the SPR:
1. Position the mounting bracket on the mounting surface (e.g. wall), and then use a
pencil to mark the position of the four mounting holes.
2. Drill holes for each hole that you marked in the step above.
3. Insert wall anchors (not supplied) into each of the drilled holes.
4. Align the mounting bracket’s four holes with the wall anchors, and then insert a
screw (not supplied) through the mounting bracket holes into each wall anchor,
and tighten.
Note: Airspan does not provide screws for attaching the mounting bracket to
the wall. The screw size depends on the structure of the building to which the
bracket is to be attached. When selecting screw sizes, consideration must be
given to the weight of the SPR and load that may be induced in windy
conditions.