Figure19:Glandconnector‐copper
1. RemovetheGlandconnectorbyunscrewingthebod yfromtheAirHarmony4200DC,
usingthe(supplied)Glandwrench.
2. PassthepreparedEthernetcablethroughthetailnut,glandseal,bodyandfrontsealof
theconnectorcasingasshownbelow.Donottightenthetailnut.
Figure20:EthernetCablethroughconnector
3. SeattheRJ45connectorplugsecurelyintothebodycavityoftheAirHarmony4200DC
4. TightentheGlandbodyintotothethreadedholeonthebottomoftheAirHarmony
4200DC.
5. TightenthetailnutontothebodyusingtheincludedGlandwrench,forcingthe
seal
compressaroundthecable.
6. Oncetheconnectorisproperlyinstalled,thecableshouldbepositionedandsecuredto
minimizestressonthecable.
5.4 Fiber Ethernet (SFP) Cable Installation
TheFiberEthernetSmallformfactorpluggabletransceiver(SFP)mustbeconnectedtothe
AirHarmony‐4200DCusinganoutdoorfibercable.Theopticalconnectionenablesaonehand
installationoftheconnector.ThisenablestheuserstoeasilyremoveandreplacetheSFPtransceiver