Installation Guide

AirHarmony4200DC(InternalFilters)InstallationGuide
UGDD01196 AirspanCommercialandInternalUse 29
4 Installing AirHarmony-4200 DC
Note:ProperclearanceisrequiredforproperplacementoftheAirHarmonyunitonpole
orwall.500mmclearanceonbottom,300mmclearanceontopand100mmclearance
onsidesandbackfromotherobjectsinthevicinity.
InstalltheAirHarmony4200DCeNodeBbypole/wallmount.AirHarmony4200DCismountedona
poleorwallincloseproximitytoitsexternalantenna(connectorizedvariant).
RemovetheAirHarmonyfromitspackaginginpreparationformounting.
Caution:Properlocalriggingandhoistingpracticesshouldbefollowedwheninstalling
theAirHarmony4200DConpoleorwall.
4.1 Connecting the GPS Antenna
PriortoinstallationoftheAirHarmonytheGPSantennashouldbeconnectedandafteritis
recommendedthattheconnectionshouldbeweatherproofed.
ThefollowingdescribestheconnectionoftheGPSantennawhichisinstalleddirectlytothetopof
theunit.
13. Removetheprotectivedustcapfromthe
GPSantennajackpriortomountingonthe
AirHarmony4200DC.
14. AligntheGPSjackwiththeplugonthetoppanelontheAirHarmony4200DC.
15. AttachtheGPSantennatotheTNCconnectorontheunit.
Figure6:AttachingGPSantennatounit

Caution:Takecarenottoovertightensoasnottodamagethethreads.
Note:Itisgoodpracticetoweatherproofalltheantennaconnections.Thisisdonewith
alayerofselfamalgamatingtapefollowedbyanoverlayerofPVCtape.Theweather
proofingtheGPSconnectionisbestdoneatthisstagetogiveeasieraccesstothe