Installation Guide
AirHarmony‐4200DC(InternalFilters)InstallationGuide
UGD‐D01196 AirspanCommercialandInternalUse 28
Environmental
AirHarmony‐4200DCInternalfiltersunitmeetsthefollowingenvironmentalrequirements:
GR‐63StorageandTransportation
ETSIEN300‐019‐1‐4Operational(non‐weatherprotectedequipment)
ETSIEN300‐019‐1‐1Storage(weatherprotected,non‐temperaturecontrolledlocations)
ETSIEN300‐019‐1‐2Transportation
Table10:AirHarmony‐4200DCEnvironmentCompliance
Type Details StandardCompliance
Operatingtemperature‐40°Cto55°C/‐40°Fto131°F
ETSI 300 019 1-4
Operatinghumidity
5% - 100% non-condensing ETSI 300 019 1-4
Storagetemperature‐40°Cto70°C N/A
Storagehumidity 5%‐100%non‐condensing ETSI3000191‐4
Rainanddustingress
protection
IP66 N/A
Operationalaltitude
70‐106kPaaswellas:
From‐60mto1800m@40C
From1800mto4200m@30C
ETSI3000191‐4
Solarradiation 1120W/m
2
ETSI3000191‐4