Installation Guide

AirHarmony-4200 DC (Internal Filters) Installation Guide
UGD-D01196 Airspan Commercial and Internal Use 29
1. Select the location on the pole to mount the AirHarmony-4200 DC. You can attach the
AirHarmony-4200 DC to any pole from 1-7/8 to 16 inches (47.6 to 406.4 mm) in diameter.
2. Determine where to position the mounting plate on the pole and mark where to drill for
insertion of the 3/8-16 through-bolt.
Note: Threaded rod and necessary hardware are not supplied by Airspan and are the
responsibility of the installer.
3. Drill a minimum 7/16” hole to accept the 3/8-16 threaded rod.
4. Thread the 3/8-16 threaded rod into the provided clinch-nut attached on the Pole/Wall
mounting plate.
5. Holding the mounting plate (with the attached threaded rod) pass the 3/8-16 threaded rod
through the drilled hole in the pole.
6. Install on the exposed thread that protrudes from pole a flat washer, split washer, and
then a 3/8”-16 hex nut and tighten.
7. Insert the clamp bands (supplied) by passing them through the slots in the mounting plate,
in three (3) places.
8. Tighten the clamp bands with large flat screwdriver.
Figure 10: Mounting plate on pole