Installation Guide
AirHarmony-4200 DC (Internal Filters) Installation Guide
UGD-D01196 Airspan Commercial and Internal Use 10
GPS Compliance
The GPS is in compliance with the essential requirements and other relevant provisions of Directive
1999/5/EC."
The GPS complies with the following EMC Common Regulatory Testing standards:
EN55022: Radiated and Conducted Emissions
CISPR 22: Class B
EN 50081-1: Generic Emissions Class B
EN 50082-1: Generic Immunity Class B
EN 61000-4-2: Electrostatic Discharge Immunity
EN 61000-4-3: Radiated RF EM Field Immunity Test
EN 61000-4-4: Electrical Fast Transient/Burst Test
EN 61000-4-6: Conducted Immunity
EN 61000-4-8: Magnetic Field Immunity
Note: A GPS is recommended for synchronizing between LTE sectors.
Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS
antenna in a remote location for lightning prone deployments.
Maximum Output TX Total Power
Table 1: AirHarmony-4200 DC Internal Filter FCC Maximum Output TX Total Power
Frequency Band
(MHz)
FCC
TX (dBm) EIRP (dBm)
Antenna Gain
(dBi)
B48 3550-3700
36.9
46.4
9.5
Note: The AirHarmony 4200 DC Internal Filters requires operation using an Airspan FCC-specific
version of Netspan acting as a CBRS Domain Proxy.
Table 2: AirHarmony-4200 DC Internal Filter ETSI Maximum Output TX Total Power
Frequency Band
(MHz)
ETSI
TX (dBm) EIRP (dBm)
Antenna Gain
(dBi)
3400-3600
39-40
TBD
18
Caution: Do not set maximum output TX power to higher than local regulations.
Power Consumption - Supply and Current
AirHarmony-4200 DC Internal Filters supports direct connection to DC power source.
DC Power Source requirements are:
Operational Voltage Range: -40.5 to -57 VDC Max, 8A Max
Safety approved (certified) according to IEC/EN/UL 60950-1