User Manual
Central Terminal Level Control Unit
Operators Manual
DLP 001
605-0000-428
Issue 1.2 Date 5/11/98
Page 4 of 4
If any errors occur the LCU will stop the level control operation and set
the operation mode to Idle automatically. When this occurs view the Error
Menu for the source of this error.
Error SH:1 0E-
Comms * Conv 0--
Sh Id Det ---
CRC Modem ---
Communications time-out error
Incorrect shelf identifier in the
received data packet
Incorrect CRC checksum in the
received data packet
Failed to converge within 15 mins
(applicable only to poll modes)
RF failure in LCU
Failed to enable the modem
associated with the RW
12. Key F6 twice Select Configuration Set-up.
13. Select Mode Select.
14. Set to the required polling interval 1 hour, 1 day, or Idle. If the shelf is left
in continuous mode it will revert to idle mode after 1 hour.
Mode SH:1 0E-
1-T
Mode:********** 0--
0--
Possible Modes
Idle
None (shelf not present)
Continuous
Hour
Day
15. Key F5 to return to the Shelf Selection Menu